An assessment of a 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F18%3AN0000070" target="_blank" >RIV/00064173:_____/18:N0000070 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21340/18:00328520

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.ejmp.2017.11.014" target="_blank" >http://dx.doi.org/10.1016/j.ejmp.2017.11.014</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.ejmp.2017.11.014" target="_blank" >10.1016/j.ejmp.2017.11.014</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    An assessment of a 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

  • Original language description

    Purpose: To provide a 3D dosimetric evaluation of a commercial portal dosimetry system using 2D/3D detectors under ideal conditions using VMAT.& para;& para;Methods: A 2D ion chamber array, radiochromic film and gel dosimeter were utilised to provide a dosimetric evaluation of transit phantom and pre-treatment 'fluence' EPID back-projected dose distributions for a standard VMAT plan. In-house 2D and 3D gamma methods compared pass statistics relative to each dosimeter and TPS dose distributions.& para;& para;Results: Fluence mode and transit EPID dose distributions back-projected onto phantom geometry produced 2D gamma pass rates in excess of 97% relative to other tested detectors and exported TPS dose planes when a 3%, 3 mm global gamma criterion was applied. Use of a gel dosimeter within a glass vial allowed comparison of measured 3D dose distributions versus EPID 3D dose and TPS calculated distributions. 3D gamma comparisons between modalities at 3%, 3 mm gave pass rates in excess of 92%. Use of fluence mode was indicative of transit results under ideal conditions with slightly reduced dose definition.& para;& para;Conclusions: 3D EPID back projected dose distributions were validated against detectors in both 2D and 3D. Cross validation of transit dose delivered to a patient is limited due to reasons of practicality and the tests presented are recommended as a guideline for 3D EPID dosimetry commissioning; allowing direct comparison between detector, TPS, fluence and transit modes. The results indicate achievable gamma scores for a complex VMAT plan in a homogenous phantom geometry and contributes to growing experience of 3D EPID dosimetry.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30224 - Radiology, nuclear medicine and medical imaging

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Physica Medica

  • ISSN

    1120-1797

  • e-ISSN

    1724-191X

  • Volume of the periodical

    45

  • Issue of the periodical within the volume

    January

  • Country of publishing house

    IT - ITALY

  • Number of pages

    10

  • Pages from-to

    25-34

  • UT code for WoS article

    000426007200005

  • EID of the result in the Scopus database

    2-s2.0-85042131568