Changes in heart rate variability in patients with atrial fibrillation after pulmonary vein isolation and ganglionated plexus ablation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F19%3AN0000074" target="_blank" >RIV/00064173:_____/19:N0000074 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11120/19:43917375
Result on the web
<a href="https://doi.org/10.33549/physiolres.933710" target="_blank" >https://doi.org/10.33549/physiolres.933710</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33549/physiolres.933710" target="_blank" >10.33549/physiolres.933710</a>
Alternative languages
Result language
angličtina
Original language name
Changes in heart rate variability in patients with atrial fibrillation after pulmonary vein isolation and ganglionated plexus ablation
Original language description
Pulmonary vein isolation (PVI) is the cornerstone in the treatment of patients with paroxysmal atrial fibrillation (PAF). Some research has suggested studies have shown that modification of ganglionated plexuses (GP), performed with PVI, could lead to even better outcomes. The aim of this study was to determine the effect of PVI on the autonomic system. Heart rate variability (HRV) was used as a marker of autonomic system activity. Twenty-six PAF patients underwent PVI (PVI group) and twenty patients underwent PVI plus a GP ablation (GP group). In each group, 5 min long ECG signals obtained before and after the electrophysiology EP study were analyzed. Time and frequency domain parameters were evaluated. Vagal responses during ablation were observed in 15 (58 %) patients in the PVI group and in 12 (60 %) patients in the GP group. The change in normalized power in the low frequency (LF) and in the LF/HF ratio, before and after ablation, was statistically significant in both groups (LF/HF 2.6+/-1.6 before vs. 1.4+/-1.7 after ablation in PVI group and LF/HF 3.3+/-2.6 before vs.1.8+/-1.9 after ablation in the GP group). Relative to heart rate variability parameters, there were no differences between PVI and PVI + plus GP ablation.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
<a href="/en/project/NV16-32478A" target="_blank" >NV16-32478A: EndoMaze HYBRID project-a detailed assessment of efficacy and safety of hybrid ablation of persistent and long-standing persistent atrial fibrillation</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Physiological Research
ISSN
0862-8408
e-ISSN
1802-9973
Volume of the periodical
68
Issue of the periodical within the volume
1
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
9
Pages from-to
49-57
UT code for WoS article
000460617400005
EID of the result in the Scopus database
2-s2.0-85062692775