The absence of effect of ganglionated plexi ablation on heart rate variability parameters in patients after thoracoscopic ablation for atrial fibrillation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F17%3A43916005" target="_blank" >RIV/00216208:11120/17:43916005 - isvavai.cz</a>
Alternative codes found
RIV/00064173:_____/17:N0000006
Result on the web
<a href="http://dx.doi.org/10.21037/jtd.2017.11.119" target="_blank" >http://dx.doi.org/10.21037/jtd.2017.11.119</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.21037/jtd.2017.11.119" target="_blank" >10.21037/jtd.2017.11.119</a>
Alternative languages
Result language
angličtina
Original language name
The absence of effect of ganglionated plexi ablation on heart rate variability parameters in patients after thoracoscopic ablation for atrial fibrillation
Original language description
Background: Hybrid ablation [thoracoscopic ablation (TA) of atrial fibrillation (AF) followed by catheter ablation (CA)] is an increasingly common method of the treatment for patients with AF. The aim of this study was to assess the response to ganglionated plexi (GP) ablation in patients with a previous TA (i.e., to assess whether TA had resulted in damage to the GP. Heart rate variability (HRV) was used as a marker of the autonomic response. Methods: Twenty AF patients underwent pulmonary vein isolation (PVI) plus GP ablation (GP group) and 18 AF patients underwent CA including GP ablation as a part of hybrid ablation (i.e., all patients had undergone a previous TA; Hybrid group). In each group, a 5 min electrocardiogram (ECG) obtained before and after the CA were analyzed. Time and frequency domain parameters were evaluated. Results: Vagal responses (VR) during CA were observed in 12 (60%) patients in the GP group; however, in the Hybrid group, VR was not observed in any of the patients during CA. The change in normalized power in the low frequency (LF) component and the ratio between the LF and high frequency (LF/HF ratio) components of the HRV spectra, before and after ablation, were statistically significant in the GP group (3.3+-2.6 before vs. 1.8+-1.9 after ablation) but unchanged, before or after CA, in the Hybrid group. Conclusions: GP ablation in patients subsequent to TA has a little influence on HRV parameters, which could be explained by GP damage during the preceding TA.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
<a href="/en/project/NV16-32478A" target="_blank" >NV16-32478A: EndoMaze HYBRID project-a detailed assessment of efficacy and safety of hybrid ablation of persistent and long-standing persistent atrial fibrillation</a><br>
Continuities
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Thoracic Disease
ISSN
2072-1439
e-ISSN
—
Volume of the periodical
9
Issue of the periodical within the volume
12
Country of publishing house
CN - CHINA
Number of pages
11
Pages from-to
4997-5007
UT code for WoS article
000419323400074