VDI Vision - Analysis of Ventricular Electrical Dyssynchrony in Real-Time
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F21%3AN0000102" target="_blank" >RIV/00064173:_____/21:N0000102 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.23919/CinC53138.2021.9662916" target="_blank" >https://doi.org/10.23919/CinC53138.2021.9662916</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.23919/CinC53138.2021.9662916" target="_blank" >10.23919/CinC53138.2021.9662916</a>
Alternative languages
Result language
angličtina
Original language name
VDI Vision - Analysis of Ventricular Electrical Dyssynchrony in Real-Time
Original language description
Background: Ventricular electrical dyssynchrony can be examined using ultra-high-frequency (UHF-ECG) analysis. Furthermore, UHF-ECG analysis would allow direct optimization of pacing therapy. Here we introduce VDI vision (Ventricular Dyssynchrony Imaging), a desktop application for the real-time processing of UHF-ECG recordings. Method: Incoming ECG data (5kHz, 26 bits, 24 channels) are processed as follows: QRS detection, pacemaker stimuli elimination, QRS clustering, amplitude envelopes in nine frequency bands, and final combination into the Ventricular Depolarization (VD) map. The VD map is updated whenever a new QRS is detected. Results: We developed the VDI vision using the. NET platform. Until the end of March 2021, the VDI monitor was used to analyze 773 and 4,849 recordings at ICRC-FNUSA hospital (Brno, Czechia) and FNKV hospital (Prague, Czechia), respectively. The median length for ICRC-FNUSA recordings was 124 (IQR 121-139) seconds. The median length for recordings at FNKV hospital was 157 seconds (IQR 127-200). Conclusion: The VDI vision delivers information about electrical ventricular dyssynchrony in real-time. The instant analysis allows using the software during implant procedures for optimizing electrode placement and pacing. The presented real-time solution also significantly minimized measurement duration.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Computing in Cardiology, Vol. 48
ISBN
978-1-66546-721-6
ISSN
—
e-ISSN
—
Number of pages
4
Pages from-to
1-4
Publisher name
IEEE
Place of publication
New Jersey
Event location
Brno
Event date
Sep 12, 2021
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—