Determination of stress and displacement on human composite pelvis under static and dynamic loading
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F22%3A43923578" target="_blank" >RIV/00064173:_____/22:43923578 - isvavai.cz</a>
Alternative codes found
RIV/68081723:_____/22:00558094 RIV/00216305:26210/22:PU144561 RIV/00216208:11120/22:43923578 RIV/27283933:_____/22:00011109
Result on the web
<a href="https://doi.org/10.1177/09544119221099805" target="_blank" >https://doi.org/10.1177/09544119221099805</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/09544119221099805" target="_blank" >10.1177/09544119221099805</a>
Alternative languages
Result language
angličtina
Original language name
Determination of stress and displacement on human composite pelvis under static and dynamic loading
Original language description
This case study describes the experimental determination of displacements and stresses on a composite model of a pelvis that was modified to represent a healthy intact pelvic ring. The modified model was stressed statically up to 1750 N to simulate standing on one leg and also cyclically to model walking. For two different model settings in the loading machine the values of displacements and stresses at the pelvic ring were determined. The two different settings correspond to two different loading vectors applied on the pelvic ring, boundary conditions and degrees of freedom. The experimentally determined values of displacements in both settings are very similar and in accordance with the knowledge on the behaviour of a real human pelvis. The modified model is thus suitable for testing of newly developed implants for pelvis treatment and experimental determination of displacements and stresses in pelvic ring which are caused by application of implants.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30211 - Orthopaedics
Result continuities
Project
<a href="/en/project/FV30219" target="_blank" >FV30219: 3D print of implants for treating of a damaged skeleton, especially the human pelvis</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
ISSN
0954-4119
e-ISSN
2041-3033
Volume of the periodical
236
Issue of the periodical within the volume
7
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
951-959
UT code for WoS article
000802946000001
EID of the result in the Scopus database
2-s2.0-85130957030