The choice of embedding media affects image quality, tissue R2 * , and susceptibility behaviors in post-mortem brain MR microscopy at 7.0T
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064190%3A_____%2F18%3AN0000096" target="_blank" >RIV/00064190:_____/18:N0000096 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11110/19:10393283 RIV/00064190:_____/19:N0000066 RIV/00064165:_____/19:10393283
Result on the web
<a href="https://doi.org/10.1002/mrm.27595" target="_blank" >https://doi.org/10.1002/mrm.27595</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/mrm.27595" target="_blank" >10.1002/mrm.27595</a>
Alternative languages
Result language
angličtina
Original language name
The choice of embedding media affects image quality, tissue R2 * , and susceptibility behaviors in post-mortem brain MR microscopy at 7.0T
Original language description
PURPOSE: The quality and precision of post-mortem MRI microscopy may vary depending on the embedding medium used. To investigate this, our study evaluated the impact of 5 widely used media on: (1) image quality, (2) contrast of high spatial resolution gradient-echo (T1 and T2 * -weighted) MR images, (3) effective transverse relaxation rate (R2 * ), and (4) quantitative susceptibility measurements (QSM) of post-mortem brain specimens. METHODS: Five formaldehyde-fixed brain slices were scanned using 7.0T MRI in: (1) formaldehyde solution (formalin), (2) phosphate-buffered saline (PBS), (3) deuterium oxide (D2 O), (4) perfluoropolyether (Galden), and (5) agarose gel. SNR and contrast-to-noise ratii (SNR/CNR) were calculated for cortex/white matter (WM) and basal ganglia/WM regions. In addition, median R2 * and QSM values were extracted from caudate nucleus, putamen, globus pallidus, WM, and cortical regions. RESULTS: PBS, Galden, and agarose returned higher SNR/CNR compared to formalin and D2 O. Formalin fixation, and its use as embedding medium for scanning, increased tissue R2 * . Imaging with agarose, D2 O, and Galden returned lower R2 * values than PBS (and formalin). No major QSM offsets were observed, although spatial variance was increased (with respect to R2 * behaviors) for formalin and agarose. CONCLUSIONS: Embedding media affect gradient-echo image quality, R2 * , and QSM in differing ways. In this study, PBS embedding was identified as the most stable experimental setup, although by a small margin. Agarose and Galden were preferred to formalin or D2 O embedding. Formalin significantly increased R2 * causing noisier data and increased QSM variance.
Czech name
—
Czech description
—
Classification
Type
J<sub>ost</sub> - Miscellaneous article in a specialist periodical
CEP classification
—
OECD FORD branch
30103 - Neurosciences (including psychophysiology)
Result continuities
Project
<a href="/en/project/NV15-25602A" target="_blank" >NV15-25602A: Biomarkers of progression and treatment response in neurodegenerative disorders</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Magnetic Resonance in Medicine
ISSN
0740-3194
e-ISSN
1522-2594
Volume of the periodical
81
Issue of the periodical within the volume
4
Country of publishing house
US - UNITED STATES
Number of pages
14
Pages from-to
2688-2701
UT code for WoS article
—
EID of the result in the Scopus database
—