Kaolin activated thromboelastography can result in false positive fibrinolytic trace
Original language description
Background The correct methodology of thrombelastography might be influenced by elapsing time. In our study we investigated kaolin activated citrated samples together with non-activated citrated samples in relation to the elapsed times of 0, 15 and 30 minutes to compare both methods and to find out if there is an impact of time on results of thrombelastography. Methods Blood samples obtained from 10 healthy volunteers were analyzed after 0, 15 and 30 minutes from sampling with kaolin activation and without activation. Then the results were analysed and compared between the non-activated and the kaolin-activated method. Results All blood samples became more hypercoagulable with the time elapsing, both in non-activated and kaolin-activated samples and differences between both groups were found statistically and clinically significant after only 0 minutes. Conclusions The non-activated citrated method seems to be reliable and suitable for thrombelastography in non-emergency cases (planned surgical procedures) when we have time to wait 15-30 minutes to get results. In urgent situations a rapid thrombelastography test should be preferred. Although the kaolin-activated method can also be used, results must be interpreted with caution.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FP - Other medical fields
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2011
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Anaesthesia and Intensive Care
ISSN
0310-057X
e-ISSN
—
Volume of the periodical
39
Issue of the periodical within the volume
4
Country of publishing house
AU - AUSTRALIA
Number of pages
2
Pages from-to
775-776
UT code for WoS article
000293264000051
EID of the result in the Scopus database
2-s2.0-80051934017