Mid-term results of revision total hip arthroplasty using the oval-shaped uncemented Trc-Cingr cup

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F14%3A10292776" target="_blank" >RIV/00064203:_____/14:10292776 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11130/14:10292776

  • Result on the web

    <a href="http://dx.doi.org/10.1007/s00264-013-2269-7" target="_blank" >http://dx.doi.org/10.1007/s00264-013-2269-7</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s00264-013-2269-7" target="_blank" >10.1007/s00264-013-2269-7</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Mid-term results of revision total hip arthroplasty using the oval-shaped uncemented Trc-Cingr cup

  • Original language description

    Purpose The aim of the present study was to introduce a novel oblong revision cup type TC for use in revision total hip arthroplasty (THA), and to evaluate mid-term results in terms of bone tissue remodelling in the immediate area of the implant. MethodsThe results of 31 patients that underwent revision THA between 2004 and 2008 are presented. The mean follow-up interval was 7.1 years (range 5.3-9.3 years, minimum of five years following revision). Osteointegration of the implant and bone tissue remodelling around the implant and ribs were assessed by X-ray and computed tomography (CT). Results The average Harris hip score increased from 39.8 to 85.3. Excellent results were achieved in nine patients, good in 16, fair in three and poor in three. According to X-ray results, 25 hips had a well-fixed, bone-ingrown cup and five had a stable fibrous union in the middle and the distal third of the implant. Proximal migration of the cup was noted in one case. Pelvic CT was additionally perfor

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FI - Traumatology and orthopaedics

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    International Orthopaedics

  • ISSN

    0341-2695

  • e-ISSN

  • Volume of the periodical

    38

  • Issue of the periodical within the volume

    5

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    6

  • Pages from-to

    935-940

  • UT code for WoS article

    000335147900004