Lot-to-lot stability of antibody reagents for flow cytometry

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F19%3A10402065" target="_blank" >RIV/00064203:_____/19:10402065 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11130/19:10402065

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=u0oUdomqJ0" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=u0oUdomqJ0</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.jim.2017.03.018" target="_blank" >10.1016/j.jim.2017.03.018</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Lot-to-lot stability of antibody reagents for flow cytometry

  • Original language description

    The fluorescence detected using fluorochrome-labelled monoclonal antibodies depends not only on the abundance of the target antigen, but amongst many other factors also on the effective fluorochrome-to-antibody ratio. The diagnostic approach of the EuroFlow consortium relies on reproducible fluorescence intensities over time. A capture bead system for mouse immunoglobulin light chains was utilized to compare the mean fluorescence intensity of 1323 consecutive antibody lots to the currently used lot of the same monoclonal antibody. In total, 157 different monoclonal antibodies were assessed over seven years. Median relative difference between consecutive lots was 3.8% (range: 0.01% to 164.7%, interquartile range: 1.3% to 10.1%). The relative difference exceeded 20% in 8.8% of all comparisons. F1TC labelled monoclonal antibodies (median relative difference: 2.1%) showed a significantly smaller variation between lots than antibodies conjugated to PE (3.5%), PECy7 (3.9%), PerCPCy5.5 (5.8%), APC (5.8%),APCH7 ( 7.4%), and APCC750 (14.5%). Reagents labelled with Pacific Blue (1.4%), Pacific Orange (2.4%), HV450 (0.7%), and HV500 (1.7%) demonstrated more consistent results compared to conjugates of BV421 (4.1%) and BV510 (16.2%). Additionally, significant differences in lot-to-lot fluorescence stability amongst antibodies labelled with the same fluorochrome were observed between manufacturers. These observations might guide future quality recommendations for the production and application of fluorescence-labelled monoclonal antibodies in multicolor flow cytometry. (C) 2017 Published by Elsevier B.V.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30204 - Oncology

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Immunological Methods

  • ISSN

    0022-1759

  • e-ISSN

  • Volume of the periodical

    475

  • Issue of the periodical within the volume

    SI

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    6

  • Pages from-to

    112294

  • UT code for WoS article

    000502791200011

  • EID of the result in the Scopus database

    2-s2.0-85018158869