All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Sonographic measurement of deep fascia parameters - Interrater reliability

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F24%3A10481961" target="_blank" >RIV/00064203:_____/24:10481961 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11130/24:10481961

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=2F9MK6FrHj" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=2F9MK6FrHj</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s00276-024-03423-9" target="_blank" >10.1007/s00276-024-03423-9</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Sonographic measurement of deep fascia parameters - Interrater reliability

  • Original language description

    PURPOSE: The deep fascia has recently been a current topic in many medical fields, including rehabilitation. Some research has already focused on assessing deep fascia, however results of individual authors differ in certain aspects. This study focuses on the inter-rater reliability of ultrasound (US) measurement of the thickness of deep fascia and loose connective tissue (LCT). The aim was to define the causes of any discrepancies in measurement that could contribute to the unification of management of evaluating fascia. METHODS: An observational study was performed including 20 healthy individuals in whom fascia lata of the anterior thigh was examined by US imaging and then measured in Image J software. Three raters participated in this study: the first with 6 years of US imaging experience, other two were newly trained. The measurement of fascial parameters was conducted in two phases with special consultation between them resulting in an agreement of the research team on the more precise way of measurement. RESULTS: Results revealed the value of inter-rater reliability ICC(3,1) = 0.454 for deep fascia thickness and ICC(3,1) = 0.265 for LCT thickness in the first phase and any significant difference in the second phase. This poor inter-rater reliability led to a search for possible causes of discrepancies, which authors subsequently highlighted. CONCLUSION: The findings of the study show the main pitfalls of deep fascia measurement that should contribute to the unification of evaluation.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30306 - Sport and fitness sciences

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2024

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Surgical and Radiologic Anatomy

  • ISSN

    0930-1038

  • e-ISSN

    1279-8517

  • Volume of the periodical

    46

  • Issue of the periodical within the volume

    9

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    9

  • Pages from-to

    1481-1489

  • UT code for WoS article

    001268707300001

  • EID of the result in the Scopus database

    2-s2.0-85198653680