Assessing the Test-Retest Reliability of MyotonPRO for Measuring Achilles Tendon Stiffness
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F25%3A10496719" target="_blank" >RIV/00216208:11130/25:10496719 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11510/25:10496719
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=5NVHvM-lP9" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=5NVHvM-lP9</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/jfmk10010083" target="_blank" >10.3390/jfmk10010083</a>
Alternative languages
Result language
angličtina
Original language name
Assessing the Test-Retest Reliability of MyotonPRO for Measuring Achilles Tendon Stiffness
Original language description
Objectives: This study evaluates the test-retest reliability and inter-rater reliability of the MyotonPRO for measuring Achilles tendon stiffness at two standardized sites over various time frames and settings. Methods: Eight healthy participants underwent assessments by three raters over six visits. Tendon stiffness was measured at proximal (mid-portion) and distal (insertional) regions of the Achilles tendon at various time frames (10-15 s, 10-15 min, 24 h, and 14 days apart). Measurements included participant repositioning and two activity stimuli (daily living and sport). Reliability was calculated using the intraclass correlation coefficient (ICC), its 95% confidence interval, coefficient of variation, standard error of measurement, and minimal detectable change. Results: Short-term reliability (10-15 min) was excellent, with an ICC of 0.956 (0.929-0.974). Between days reliability (24 h) was good, with an ICC of 0.889 (0.802-0.938). Between weeks reliability (2 weeks) was good with an ICC of 0.886 (0.811-0.931). Short-term reliability with the simulation of activity of daily living was good, with an ICC of 0.917 (0.875-0.945). Short-term reliability with the simulation of sport was good with an ICC of 0.933 (0.891-0.96). Between days reliability with the simulation of sport was good, with an ICC of 0.920 (0.859-0.955). Conclusions: When used in a standardized position, the MyotonPRO demonstrates reliable repeated measurements of Achilles tendon stiffness. This protocol provides a foundation for clinical research and rehabilitation by clarifying expected reliability across minutes, days, and weeks, thus aiding clinicians and researchers in monitoring tendon adaptations and making evidence-based decisions.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30306 - Sport and fitness sciences
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Functional Morphology and Kinesiology
ISSN
2411-5142
e-ISSN
2411-5142
Volume of the periodical
10
Issue of the periodical within the volume
1
Country of publishing house
CH - SWITZERLAND
Number of pages
13
Pages from-to
83
UT code for WoS article
001482859700001
EID of the result in the Scopus database
2-s2.0-105001099679