Comparison of various methods of ischaemic cardioprotection on vitality of rat heart grafts
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F17%3A00067049" target="_blank" >RIV/00159816:_____/17:00067049 - isvavai.cz</a>
Alternative codes found
RIV/62157124:16170/17:43875748 RIV/62157124:16370/17:43875748
Result on the web
<a href="http://dx.doi.org/10.2754/avb201786020199" target="_blank" >http://dx.doi.org/10.2754/avb201786020199</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2754/avb201786020199" target="_blank" >10.2754/avb201786020199</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of various methods of ischaemic cardioprotection on vitality of rat heart grafts
Original language description
The aim of the study was to compare 4 modes of ischaemic cardioprotection using continuous prograde autologous blood perfusion of the coronary artery in two hypothermic modes (group A, B) or conventional protection by cooled Hartmann solution (group C) or cooled saline (group D) without perfusion of the graft. Male Wistar rats (n = 24) were divided into four groups (A-D). In groups A (22-25 oC) and B (4-8 oC), blood perfusion rate was 10 ml/h and the graft was placed in a water bath. Groups C, D were initially rinsed with cold (4-8 oC) Hartmann solution (C) and cold saline solution (D), next the graft was placed in a water bath of cold (4-8 oC) Hartmann solution (C) or saline solution (D). The observed time was 30 min after the implemented perfusion (A, B) or initial rinsing (C, D). At 30 min, hearts of all the groups were perfused for 10 min with prograde-autologous arterialized blood at room temperature. At perfusion minute 10, blood was collected for biochemical analysis (sample 1). Sample 2 involved blood from a portable syringe infusion pumps (in parallel with sample 1). Pairwise test differences between samples 1 and 2 were signifcant in all the groups as regards creatine kinase and lactate dehydrogenase values, sampling 1 values being always higher, while cardiac troponin I concentrations were nonsignifcant in the same comparison. The heart rate during the fnal perfusion was identical in all the groups. Our study has demonstrated that all observed cardioprotection modes are useful for experimental heart grafting
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
40301 - Veterinary science
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Acta Veterinaria Brno
ISSN
0001-7213
e-ISSN
—
Volume of the periodical
86
Issue of the periodical within the volume
2
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
8
Pages from-to
199-206