All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Epicardial Isochrones From a New High-Frequency ECG Imaging Technique

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F18%3A00072527" target="_blank" >RIV/00159816:_____/18:00072527 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.22489/CinC.2018.088" target="_blank" >http://dx.doi.org/10.22489/CinC.2018.088</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.22489/CinC.2018.088" target="_blank" >10.22489/CinC.2018.088</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Epicardial Isochrones From a New High-Frequency ECG Imaging Technique

  • Original language description

    The aim of this study is to compare epicardial isochrone maps (EIM) derived from electrocardiographic (ECG) imaging with a new technique based on high frequency ECG isochrone maps (HFEIM) computation. We analyzed three subjects - normal, left bundle branch block (LBBB) and right bundle branch block (RBBB). Body surface potentials were measured: 5-minute supine, 2KHz sampling, 184 electrodes. These potentials were used for inverse reconstruction of EIM using patient-specific torsoheart geometry (CT). HFEIM was determined as follows: averaged body surface QRS amplitude envelopes 150-400 Hz (HFQRS) were projected onto the epicardium, the time delay from the onset of the QRS complex to centers of mass of projected HFQRS was computed. The EIM and HFEIM pattern of electrical activation was similar, especially for LBBB and RBBB subjects. The correlation between EIM and HFEIM activation times was 0.42, 0.82 and 0.83 for the NORMAL, LBBB and RBBB subjects respectively. Maximal dyssynchrony was about 40 ms lower for HFEIM than for EIM. EIM and HFEIM provide comparable distribution of electrical delays but different reference values. Lower HFEIM dyssynchrony may reflect the electrical activation in an entire ventricular wall segment and may better correlate with local electro-mechanical function.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    2018 COMPUTING IN CARDIOLOGY CONFERENCE (CINC)

  • ISBN

    978-1-72810-958-9

  • ISSN

    2325-8861

  • e-ISSN

  • Number of pages

    4

  • Pages from-to

    4

  • Publisher name

    IEEE

  • Place of publication

    NEW YORK

  • Event location

    Maastricht

  • Event date

    Sep 23, 2018

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000482598700276