Safety and efficacy of sonothrombolysis for acute ischaemic stroke: a multicentre, double-blind, phase 3, randomised controlled trial
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F19%3A00071069" target="_blank" >RIV/00159816:_____/19:00071069 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/19:00112519
Result on the web
<a href="https://www.sciencedirect.com/science/article/abs/pii/S1474442219300262" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S1474442219300262</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/S1474-4422(19)30026-2" target="_blank" >10.1016/S1474-4422(19)30026-2</a>
Alternative languages
Result language
angličtina
Original language name
Safety and efficacy of sonothrombolysis for acute ischaemic stroke: a multicentre, double-blind, phase 3, randomised controlled trial
Original language description
Background Pulsed-wave ultrasound increases the exposure of an intracranial thrombus to alteplase (recombinant tissue plasminogen activator), potentially facilitating early reperfusion. We aimed to ascertain if a novel operator-independent transcranial ultrasound device delivering low-power high-frequency ultrasound could improve functional outcome in patients treated with alteplase after acute ischaemic stroke. Methods We did a multicentre, double-blind, phase 3, randomised controlled trial (CLOTBUST-ER) at 76 medical centres in 14 countries. We included patients with acute ischaemic stroke (National Institutes of Health Stroke Scale score >= 10) who received intravenous thrombolysis (alteplase bolus) within 3 h of symptom onset in North America and within 4.5 h of symptom onset in all other countries. Participants were randomly allocated (1:1) via an interactive web response system to either active ultrasound (2 MHz pulsed-wave ultrasound for 120 min [sonothrombolysis]; intervention group) or sham ultrasound (control group). Ultrasound was delivered using an operator-independent device, which had to be activated within 30 min of the alteplase bolus. Participants, investigators, and those assessing outcomes were unaware of group assignments. The primary outcome was improvement in the modified Rankin Scale score at 90 days in patients enrolled within 3 h of symptom onset, assessed in the intention-to-treat population as a common odds ratio (cOR) using ordinal logistic regression shift analysis. This trial is registered with ClinicalTrials.gov , number NCT01098981. The trial was stopped early by the funder after the second interim analysis because of futility. Findings Between August, 2013, and April, 2015, 335 patients were randomly allocated to the intervention group and 341 patients to the control group. Compared with the control group, the adjusted cOR for an improvement in modified Rankin Scale score at 90 days in the intervention group was 1.05 (95% CI 0.77-1.45; p=0.74). 51 (16%) of 317 patients in the intervention group and 44 (13%) of 329 patients in the control group died (unadjusted OR 1.24, 95% CI 0 .80-1. 92; 13=0.37) and 83 (26%) and 79 (24%), respectively, had serious adverse events (1.12, 0.79-1.60; p=0.53). Interpretation Sonothrombolysis delivered by an operator-independent device to patients treated with alteplase after acute ischaemic stroke was feasible and most likely safe, but no clinical benefit was seen at 90 days. Sonothrombolysis could be further investigated either in randomised trials undertaken in stroke centres that are dependent on patient transfer for endovascular reperfusion therapies or in countries where these treatments cannot yet be offered as the standard of care. Copyright (C) 2019 Elsevier Ltd. All rights reserved.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30210 - Clinical neurology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Lancet Neurology
ISSN
1474-4422
e-ISSN
—
Volume of the periodical
18
Issue of the periodical within the volume
4
Country of publishing house
US - UNITED STATES
Number of pages
10
Pages from-to
338-347
UT code for WoS article
000461169400011
EID of the result in the Scopus database
—