Extracellular volume quantification using synthetic haematocrit assessed from native and post-contrast longitudinal relaxation T1 times of a blood pool
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F21%3A00075091" target="_blank" >RIV/00159816:_____/21:00075091 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/21:00122063
Result on the web
<a href="https://bmccardiovascdisord.biomedcentral.com/articles/10.1186/s12872-021-02179-z" target="_blank" >https://bmccardiovascdisord.biomedcentral.com/articles/10.1186/s12872-021-02179-z</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s12872-021-02179-z" target="_blank" >10.1186/s12872-021-02179-z</a>
Alternative languages
Result language
angličtina
Original language name
Extracellular volume quantification using synthetic haematocrit assessed from native and post-contrast longitudinal relaxation T1 times of a blood pool
Original language description
Background In terms of cardiovascular magnetic resonance are haematocrit values required for calculation of extracellular volume fraction (ECV). Previously published studies have hypothesized that haematocrit could be calculated from T1 blood pool relaxation time, however only native T1 relaxation time values have been used and the resulting formulae had been both in reciprocal and linear proportion. The aim of the study was to generate a synthetic haematocrit formula from only native relaxation time values first, calculate whether linear or reciprocal model is more precise in haematocrit estimation and then determine whether adding post-contrast values further improve its precision. Methods One hundred thirty-nine subjects underwent CMR examination. Haematocrit was measured using standard laboratory methods. Afterwards T1 relaxation times before and after the application of a contrast agent were measured and a statistical relationship between these values was calculated. Results Different linear and reciprocal models were created to estimate the value of synthetic haematocrit and ECV. The highest coefficient of determination was observed in the combined reciprocal model "- 0.047 + (779/ blood native) - (11.36/ blood post-contrast)". Conclusions This study provides more evidence that assessing synthetic haematocrit and synthetic ECV is feasible and statistically most accurate model to use is reciprocal. Adding post-contrast values to the calculation was proved to improve the precision of the formula statistically significantly.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
<a href="/en/project/LQ1605" target="_blank" >LQ1605: Translational Medicine</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
BMC Cardiovascular disorders
ISSN
1471-2261
e-ISSN
—
Volume of the periodical
21
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
8
Pages from-to
—
UT code for WoS article
000679726500001
EID of the result in the Scopus database
—