Clinical outcomes and survival comparison between NexGen all-poly and its metal-backed equivalent in total knee arthroplasty
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F23%3A00078678" target="_blank" >RIV/00159816:_____/23:00078678 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/23:00131204
Result on the web
<a href="https://link.springer.com/article/10.1007/s00264-023-05772-3" target="_blank" >https://link.springer.com/article/10.1007/s00264-023-05772-3</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00264-023-05772-3" target="_blank" >10.1007/s00264-023-05772-3</a>
Alternative languages
Result language
angličtina
Original language name
Clinical outcomes and survival comparison between NexGen all-poly and its metal-backed equivalent in total knee arthroplasty
Original language description
PurposeThis study aims to compare total knee replacement (TKA) with NexGen All-Poly (APT) and NexGen Metal-Backed (MBT) in terms of implant survivorship, reasons leading to implant failure and functional results of defined age categories.MethodsA single-centre, retrospective evaluation of 812 patients who underwent knee replacement with NexGen CR between 2005 and 2021, comparing a modern congruent APT component to a modular MBT equivalent component using a similar surgical technique at a notable mean follow-up duration. Implant survival, functional outcomes using the Knee Society Score and range of motion were evaluated and compared in different age categories.ResultsOf the 812 NexGen CR TKAs performed at our institution, 410 (50.4%) used APT components and 402 (49.6%) MBT components. The survival rate of NexGen APT was 97.1% and that of NexGen MBT was 93.2% (p = 0.36). Removal of the implant occurred overall in 15 cases, for MBT in ten cases, and for APT in four cases. The FS was proved to be significantly higher when APT components were implanted in younger patients than for MBT (p = 0.005). A similar range of motion between the components was recorded (p = 0.1926).ConclusionUnder defined conditions, we measured the clinical results of implants from a single manufacturer implanted in a single department using a similar surgical technique. Considering the limitations, we suggest that all-polyethylene tibial components are equal or even superior to metal-backed ones across the examined age categories.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30211 - Orthopaedics
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
INTERNATIONAL ORTHOPAEDICS
ISSN
0341-2695
e-ISSN
1432-5195
Volume of the periodical
47
Issue of the periodical within the volume
9
Country of publishing house
US - UNITED STATES
Number of pages
7
Pages from-to
2207-2213
UT code for WoS article
000970731400001
EID of the result in the Scopus database
2-s2.0-85153065381