Biomechanical comparison of all-polyethylene total knee replacement and its metal-backed equivalent on periprosthetic tibia using the finite element method
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F24%3APU151059" target="_blank" >RIV/00216305:26210/24:PU151059 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/24:00135893 RIV/00159816:_____/24:00080566
Result on the web
<a href="https://josr-online.biomedcentral.com/articles/10.1186/s13018-024-04631-0" target="_blank" >https://josr-online.biomedcentral.com/articles/10.1186/s13018-024-04631-0</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s13018-024-04631-0" target="_blank" >10.1186/s13018-024-04631-0</a>
Alternative languages
Result language
angličtina
Original language name
Biomechanical comparison of all-polyethylene total knee replacement and its metal-backed equivalent on periprosthetic tibia using the finite element method
Original language description
BackgroundTotal knee arthroplasty (TKA) with all-polyethylene tibial (APT) components has shown comparable survivorship and clinical outcomes to that with metal-backed tibial (MBT). Although MBT is more frequently implanted, APT equivalents are considered a low-cost variant for elderly patients. A biomechanical analysis was assumed to be suitable to compare the response of the periprosthetic tibia after implantation of TKA NexGen APT and MBT equivalent.MethodsA standardised load model was used representing the highest load achieved during level walking. The geometry and material models were created using computed tomography data. In the analysis, a material model was created that represents a patient with osteopenia.ResultsThe equivalent strain distribution in the models of cancellous bone with an APT component showed values above 1000 mu epsilon in the area below the medial tibial section, with MBT component were primarily localised in the stem tip area. For APT variants, the microstrain values in more than 80% of the volume were in the range from 300 to 1500 mu epsilon, MBT only in less than 64% of the volume.ConclusionThe effect of APT implantation on the periprosthetic tibia was shown as equal or even superior to that of MBT despite maximum strain values occurring in different locations. On the basis of the strain distribution, the state of the bone tissue was analysed to determine whether bone tissue remodelling or remodelling would occur. Following clinical validation, outcomes could eventually modify the implant selection criteria and lead to more frequent implantation of APT components.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30200 - Clinical medicine
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Orthopaedic Surgery and Research
ISSN
1749-799X
e-ISSN
—
Volume of the periodical
19
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
12
Pages from-to
„153“-„“
UT code for WoS article
001168403100001
EID of the result in the Scopus database
2-s2.0-85185963224