Staining Tissues with Basic Blue 7: A New Dual-Polarity Matrix for MALDI Mass Spectrometry Imaging
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F25%3A00082456" target="_blank" >RIV/00159816:_____/25:00082456 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14310/25:00140586
Result on the web
<a href="https://pubs.acs.org/doi/10.1021/acs.analchem.4c05244" target="_blank" >https://pubs.acs.org/doi/10.1021/acs.analchem.4c05244</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acs.analchem.4c05244" target="_blank" >10.1021/acs.analchem.4c05244</a>
Alternative languages
Result language
angličtina
Original language name
Staining Tissues with Basic Blue 7: A New Dual-Polarity Matrix for MALDI Mass Spectrometry Imaging
Original language description
Obtaining high-quality matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) images and the reproducibility of the technique depend strongly on the sample preparation protocol. The most crucial part is the application of the MALDI matrix, which often relies on expensive spraying or sublimation coaters. In this work, we present a new dual-polarity matrix for MALDI mass spectrometry imaging (MSI): Basic Blue 7 (BB7), which belongs to the group of triarylmethane dyes. Thanks to its good solubility in water, this matrix allows a quick and simple sample preparation protocol without the need for sophisticated spraying or sublimation instrumentation: dipping the glass with tissue into the dye solution. This technique closely resembles the staining methods employed in classical histopathology. The technique is demonstrated on MSI of lipids in mouse brain sections in positive and negative ion modes using a subatmospheric pressure MALDI source coupled with an orbital trap mass spectrometer. The results are compared with traditional matrices, such as 2,5-dihydroxybenzoic acid (DHB) and 1,5-diaminonaphthalene (DAN). BB7 excels, especially in negative ion mode, offering low background signals and high signal intensities of many lipid classes. Furthermore, the stained tissue can simply be inspected visually and allows basic histopathology annotation prior to MSI. Here, we demonstrate that staining offers excellent image quality, reproducible sample preparation, and the potential for automation and utilization for high spatial resolution MSI.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
<a href="/en/project/GA24-10924S" target="_blank" >GA24-10924S: Digital multiplex mass spectrometry imaging</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Analytical Chemistry
ISSN
0003-2700
e-ISSN
1520-6882
Volume of the periodical
97
Issue of the periodical within the volume
5
Country of publishing house
US - UNITED STATES
Number of pages
9
Pages from-to
2828-2836
UT code for WoS article
001409957900001
EID of the result in the Scopus database
—