Measuring and Monte Carlo Modelling of X-Ray and Gamma-Ray Attenuation in Personal Radiation Shielding Protective Clothing

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F19%3AN0000072" target="_blank" >RIV/00177016:_____/19:N0000072 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.hindawi.com/journals/cmmm/2019/1641895/" target="_blank" >https://www.hindawi.com/journals/cmmm/2019/1641895/</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1155/2019/1641895" target="_blank" >10.1155/2019/1641895</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Measuring and Monte Carlo Modelling of X-Ray and Gamma-Ray Attenuation in Personal Radiation Shielding Protective Clothing

  • Original language description

    A collection of personal radiation shielding protective clothing, suitable for use in case of accidents in nuclear facilities or radiological emergency situations involving radioactive agents, was gathered and tested at the Nuclear Protection Department of the National Institute for Nuclear, Chemical and Biological Protection, Czech Republic. Attenuating qualities of shielding layers in individual protective clothing were tested via spectra measurement of x and gamma rays, penetrating them. The rays originated from different radionuclide point sources, the gamma ray energies of which cover a broad energy range. The spectra were measured by handheld spectrometers, both scintillation and High Purity Germanium. Different narrow beam geometries were adjusted using a special testing bench and a set of various collimators. The main experimentally determined quantity for individual samples of personal radiation shielding protective clothing was x and gamma rays attenuation for significant energies of the spectra. The attenuation was assessed comparing net peak areas (after background subtraction) in spectra, where a tested sample was placed between the source and the detector, and corresponding net peak areas in spectra, measured without the sample. Mass attenuation coefficients, which describe attenuating qualities of shielding layers materials in individual samples, together with corresponding lead equivalents, were determined as well. Experimentally assessed mass attenuation coefficients of the samples were compared to the referred ones for individual heavy metals.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>ost</sub> - Miscellaneous article in a specialist periodical

  • CEP classification

  • OECD FORD branch

    10301 - Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Hindawi

  • ISSN

    2356-6140

  • e-ISSN

    1537-744X

  • Volume of the periodical

    1

  • Issue of the periodical within the volume

    2019

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    8

  • Pages from-to

    1-8

  • UT code for WoS article

  • EID of the result in the Scopus database