All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Voxel Size Calibration for High-resolution CT

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F20%3AN0000081" target="_blank" >RIV/00177016:_____/20:N0000081 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216305:26620/20:PU135523 RIV/00216305:26620/20:PU135525

  • Result on the web

    <a href="https://www.ndt.net/search/docs.php3?id=25109" target="_blank" >https://www.ndt.net/search/docs.php3?id=25109</a>

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Voxel Size Calibration for High-resolution CT

  • Original language description

    In cone-beam X-ray computed tomography (CT), distances between the source, object, and detector influence the visual fidelity and voxel size of a reconstructed volume. Calibration using reference objects is an appropriate tool for preventing errors in the estimates of these distances. There is, however, a lack of such objects for high-resolution systems with a small field of view (FoV). In this work, we propose a method to measure the distances mentioned above, improving the determination of voxel size. We use a custom reference object suitable for a FoV of around one millimeter. Many approaches have been developed for this calibration task and discussed in the literature, but none apply to CT scanners with a small FoV and a cone-beam magnification close to one. The proposed method thus aims to provide a calibration procedure for such devices. A Rigaku Nano3DX CT scanner has been calibrated through this method and used for practical validation of the method's accuracy. Results have shown that this approach allows for accurate calibration, which leads to improvements in reconstruction quality and accuracy of voxel size determination.

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

  • OECD FORD branch

    21100 - Other engineering and technologies

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů