All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Practical X-ray beam spectrometry with cadmium telluride detector in 10-300 kVp range at Czech Metrology Institute. Part II. Unfolding

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F22%3AN0000028" target="_blank" >RIV/00177016:_____/22:N0000028 - isvavai.cz</a>

  • Result on the web

    <a href="https://iopscience.iop.org/article/10.1088/1748-0221/17/10/P10003" target="_blank" >https://iopscience.iop.org/article/10.1088/1748-0221/17/10/P10003</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1748-0221/17/10/P10003" target="_blank" >10.1088/1748-0221/17/10/P10003</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Practical X-ray beam spectrometry with cadmium telluride detector in 10-300 kVp range at Czech Metrology Institute. Part II. Unfolding

  • Original language description

    The paper summarizes computational methods and software tools used at Czech Metrol-ogy Institute for unfolding of X-ray photon fluence spectra from detector spectra measured with a cadmium telluride (CdTe) spectrometer directly in the X-ray beam. Fluence spectra were determined using multi-channel unfolding software GRAVEL. Response functions were calculated by Monte Carlo (MC) method using the general-purpose code MCNP (R) in version 6.2 with EPRDATA14 photon cross-section tables. The detailed MC model of the CdTe spectrometer was developed and it was validated by comparison with full-energy peak detection efficiencies measured with selected radionuclide sources. The adopted methods and tools enable to fulfil requirements of the ISO 4037 standard dealing with the necessity of direct measurement of X-ray beam photon fluence spectra whose parameters do not comply with the ones listed in the standard. The instrumentation part for the X-ray beam spectrometry at CMI is described in a separate paper [1].

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10304 - Nuclear physics

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Instrumentation

  • ISSN

    1748-0221

  • e-ISSN

  • Volume of the periodical

    17

  • Issue of the periodical within the volume

    10

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    21

  • Pages from-to

  • UT code for WoS article

    000868939700002

  • EID of the result in the Scopus database

    2-s2.0-85139564632