All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Deliverable D3: Validation of traceability chains for the absorbed dose rate to water

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F23%3AN0000084" target="_blank" >RIV/00177016:_____/23:N0000084 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Deliverable D3: Validation of traceability chains for the absorbed dose rate to water

  • Original language description

    In this work, a methodology to determine the absorbed dose rate to water distribution from electronic brachytherapy (eBT) units is suggested. It involves measuring directly in a full scatter water tank with small active detectors whose energy response at low X-ray photon energies have been previously characterized. Dose distributions of an INTRABEAM PRS 500 system in two configurations - bare needle and with the spherical applicator of 40 mm diameter - were measured in water using the Exradin A26 ionization chamber and the PTW 60019 microDiamond detector. The continuous energy response of these two detectors in terms of air kerma from 5 keV to 70 keV (eBT energy range) was available from a previous calibration at several X-ray radiation qualities. Here, it is converted to the response in absorbed dose to water using correction factors obtained with Monte Carlo (MC) particle transport simulations. The detectors were modelled using the MCNP code. The air kerma calibration factors were simulated and compared with measurements to refine and validate the models. A series of simulations of the experimental arrangement of the INTRABEAM and the detector were carried out for determining the system specific detector correction factors. These values are distance-dependent due to the steep dose gradient and the remarkable spectral changes around the eBT source in water. The dose rate with distance from the source, the radial and the polar distributions of the INTRABEAM are reported and compared with the manufacturers supplied data. This work is an effort to provide traceability for detectors and measurement procedures for the determination of 3D dose distributions as part of the European joint research project “Primary standards and traceable measurement methods for X-ray emitting electronic brachytherapy devices” (18NRM02 PRISM-eBT).

  • Czech name

  • Czech description

Classification

  • Type

    V<sub>souhrn</sub> - Summary research report

  • CEP classification

  • OECD FORD branch

    10304 - Nuclear physics

Result continuities

  • Project

    <a href="/en/project/8B19003" target="_blank" >8B19003: Primary standards and traceable measurement methods for X-ray emitting electronic brachytherapy devices</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Number of pages

    24

  • Place of publication

    PTB Branschweig, Německo

  • Publisher/client name

    EURAMET

  • Version