Uncertainty analysis of traceable measurements of pulsed magnetic fields used in magnetotherapy
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F24%3AN0000007" target="_blank" >RIV/00177016:_____/24:N0000007 - isvavai.cz</a>
Result on the web
<a href="https://zenodo.org/records/12513685" target="_blank" >https://zenodo.org/records/12513685</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33542/EMSA-0340-1" target="_blank" >10.33542/EMSA-0340-1</a>
Alternative languages
Result language
angličtina
Original language name
Uncertainty analysis of traceable measurements of pulsed magnetic fields used in magnetotherapy
Original language description
One of the practical applications of pulsed magnetic fields (PMF) is in magnetotherapy systems. These systems often generate low-frequency PMF for non-invasive therapy of muscles or bones. Some PMF system manufacturers use commercial teslameters with a Hall probe to measure the generated amplitude of the magnetic flux density Bm. However, the traceability and accuracy measurements of Bm of PMF using a Hall probe is an issue. There are papers describing methods using various types of search coils or pick-up coils with a digital oscilloscope or a DAQ device [1] for this kind of measurement, but they offer no stated traceability or detailed uncertainty analysis. Integration of the induced voltage pulse using an integrator is needed in order to calculate the measured value of Bm. A method using a special PCB search coil [2] with a digital oscilloscope has been developed at CMI. The method has been tested on pulse magnetic field signals (Fig. 1) with repeating frequencies of 40 Hz and 140 Hz (generated Bm value of about 2 mT and about 12 mT). This method can be used without using an integrator, and the Bm value is determined directly from the sampled pulse parameters. However, the expanded uncertainty value of the measurement is quite high (about 40 % in the worst case for a Bm value of about 2 mT using a DSO-X 4024A oscilloscope). A comparison was performed between the use of an 8-bit (DSO-X 4024A) and a 16-bit (PicoScope 5444D) digital oscilloscope. Further, the method was improved using a 3458A digital multimeter as a digitizer, which significantly reduced the expanded uncertainty of the measurement (about 3 % for a Bm value of about 2 mT). The measurement results obtained using the 3458A multimeter were compared to the results obtained using digital oscilloscopes and also with measurements obtained by various teslameters with Hall probes. A description will be presented of the method, the results and a detailed uncertainty analysis using digital oscilloscopes and a 3458A multimeter.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20201 - Electrical and electronic engineering
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
The XIV. European Magnetic Sensors and Actuators Conference - Book of Abstracts
ISBN
978-80-574-0340-1
ISSN
—
e-ISSN
—
Number of pages
1
Pages from-to
—
Publisher name
ŠafárikPress Publishing, Pavol Jozef Šafárik University in Košice
Place of publication
Košice, Slovensko
Event location
Košice, Slovensko
Event date
Jan 1, 2024
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—