All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Uncertainty analysis of traceable measurements of pulsed magnetic fields used in magnetotherapy

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00177016%3A_____%2F25%3AN0000005" target="_blank" >RIV/00177016:_____/25:N0000005 - isvavai.cz</a>

  • Result on the web

    <a href="https://ieeexplore.ieee.org/document/10684268" target="_blank" >https://ieeexplore.ieee.org/document/10684268</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/TMAG.2024.3463701" target="_blank" >10.1109/TMAG.2024.3463701</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Uncertainty analysis of traceable measurements of pulsed magnetic fields used in magnetotherapy

  • Original language description

    Low-frequency pulsed magnetic fields (PMFs) are often used in magnetotherapy for noninvasive therapy of muscles or bones. An oscilloscope with some kind of search coil or pickup coil can be used for measuring a PMF value. The integration of the induced voltage from the search coil using an integrator is needed in order to calculate the measured value. This article presents a traceable method with a PCB search coil and with a digital oscilloscope for measuring the PMF directly from the induced voltage without using an integrator. A detailed uncertainty analysis has been described. The method has been tested on PMF signals with repeating frequencies of 40 and 140 Hz. A comparison was performed between the use of an 8 bit (DSO-X 4024A) and a 16 bit (PicoScope 5444D) digital oscilloscope. Furthermore, the method was improved using a 3458A digital multimeter as a digitizer, which significantly reduced the expanded uncertainty of the measurement. The measurement results obtained using the 3458A multimeter were compared to the results obtained using digital oscilloscopes and also with measurements obtained by some commercial teslameters with Hall probes.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    IEEE Transactions on Magnetics

  • ISSN

  • e-ISSN

    1941-0069

  • Volume of the periodical

    61

  • Issue of the periodical within the volume

    6

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    4

  • Pages from-to

    1-4

  • UT code for WoS article

    001499319000037

  • EID of the result in the Scopus database