All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Fixation of the Ajust minisling based upon cadaveric study

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F13%3A10191755" target="_blank" >RIV/00216208:11110/13:10191755 - isvavai.cz</a>

  • Alternative codes found

    RIV/00064165:_____/13:10191755

  • Result on the web

    <a href="http://dx.doi.org/10.1007/s00192-013-2139-2" target="_blank" >http://dx.doi.org/10.1007/s00192-013-2139-2</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s00192-013-2139-2" target="_blank" >10.1007/s00192-013-2139-2</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Fixation of the Ajust minisling based upon cadaveric study

  • Original language description

    Introduction and hypothesis The objective was to describe the fixation site of the anchor of the Ajust mid-urethral minisling. Methods This cadaveric study was based on a group of 11 formalin-embalmed bodies with legs positioned in 30 degrees flexion and30 degrees abduction, and a group of five fresh-frozen bodies with legs positioned as normal during the procedure. The groups were later compared. The fixation site was dissected and described. The distance to the obturator bundle was considered as theprimary safety parameter. To compare the groups of fresh-frozen bodies and formalin-embalmed bodies, the Student's t test and Mann-Whitney test were used. Results In the group of formalin-embalmed bodies the mean distance from the anchoring device to theobturator nerve was 4.23 cm. In 19 cases out of 22 the anchor was within the complex of the obturator membrane and obturator muscles. In the group of fresh frozen bodies the mean distance to the obturator nerve was 3.15 cm. In 9 cases ou

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FK - Gynaecology and obstetrics

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/NT14162" target="_blank" >NT14162: Comparison of the safety and peri-operative complications of transobturatory introduced Tension free vaginal tape TVT-O with single incision tape with adjustable length with anchoring mechanism (Ajust) in randomized trial.</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    International Urogynecology Journal

  • ISSN

    0937-3462

  • e-ISSN

  • Volume of the periodical

    24

  • Issue of the periodical within the volume

    12

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    5

  • Pages from-to

    2119-2123

  • UT code for WoS article

    000328132300020

  • EID of the result in the Scopus database