Fixation of the Ajust minisling based upon cadaveric study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F13%3A10191755" target="_blank" >RIV/00216208:11110/13:10191755 - isvavai.cz</a>
Alternative codes found
RIV/00064165:_____/13:10191755
Result on the web
<a href="http://dx.doi.org/10.1007/s00192-013-2139-2" target="_blank" >http://dx.doi.org/10.1007/s00192-013-2139-2</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00192-013-2139-2" target="_blank" >10.1007/s00192-013-2139-2</a>
Alternative languages
Result language
angličtina
Original language name
Fixation of the Ajust minisling based upon cadaveric study
Original language description
Introduction and hypothesis The objective was to describe the fixation site of the anchor of the Ajust mid-urethral minisling. Methods This cadaveric study was based on a group of 11 formalin-embalmed bodies with legs positioned in 30 degrees flexion and30 degrees abduction, and a group of five fresh-frozen bodies with legs positioned as normal during the procedure. The groups were later compared. The fixation site was dissected and described. The distance to the obturator bundle was considered as theprimary safety parameter. To compare the groups of fresh-frozen bodies and formalin-embalmed bodies, the Student's t test and Mann-Whitney test were used. Results In the group of formalin-embalmed bodies the mean distance from the anchoring device to theobturator nerve was 4.23 cm. In 19 cases out of 22 the anchor was within the complex of the obturator membrane and obturator muscles. In the group of fresh frozen bodies the mean distance to the obturator nerve was 3.15 cm. In 9 cases ou
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FK - Gynaecology and obstetrics
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/NT14162" target="_blank" >NT14162: Comparison of the safety and peri-operative complications of transobturatory introduced Tension free vaginal tape TVT-O with single incision tape with adjustable length with anchoring mechanism (Ajust) in randomized trial.</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
International Urogynecology Journal
ISSN
0937-3462
e-ISSN
—
Volume of the periodical
24
Issue of the periodical within the volume
12
Country of publishing house
GB - UNITED KINGDOM
Number of pages
5
Pages from-to
2119-2123
UT code for WoS article
000328132300020
EID of the result in the Scopus database
—