An anatomic comparison of the original versus a modified inside-out transobturator procedure
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F11%3A00003411" target="_blank" >RIV/00216208:11120/11:00003411 - isvavai.cz</a>
Alternative codes found
RIV/00023698:_____/11:#0000067
Result on the web
<a href="http://dx.doi.org/10.1007/s00192-011-1415-2" target="_blank" >http://dx.doi.org/10.1007/s00192-011-1415-2</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00192-011-1415-2" target="_blank" >10.1007/s00192-011-1415-2</a>
Alternative languages
Result language
angličtina
Original language name
An anatomic comparison of the original versus a modified inside-out transobturator procedure
Original language description
The objective of this study was to evaluate the modification of a shortened tape and reduced dissection of the inside-out transobturator procedure on the tape's relationship to the relevant anatomical structures. In ten fresh frozen cadavers, relevant distances between the two different tapes and anatomical structures were recorded. The shorter tape traversed less muscular structures, but consistently traversed the obturator membrane. The median distance from the tape to the obturator canal measured 2.0versus 1.9 cm, to the anterior obturator nerve 3.0 versus 2.7 cm, and to the posterior obturator nerve 2.2 versus 2.0 cm [modified versus original procedure, respectively (p>0.05)]. Significantly, less mesh was inserted in the modified procedure on eachside of the body (6.1 versus 9.9 cm, p<0.05). The shorter, inside-out transobturator tape traverses less muscular structures than its original counterpart, while still consistently anchoring in the obturator membrane at a similarly safe
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
EA - Morphology and cytology
OECD FORD branch
—
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2011
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
International Urogynecology Journal
ISSN
0937-3462
e-ISSN
—
Volume of the periodical
22
Issue of the periodical within the volume
8
Country of publishing house
GB - UNITED KINGDOM
Number of pages
8
Pages from-to
997-1004
UT code for WoS article
000294351000016
EID of the result in the Scopus database
—