The Use of Continuous Glucose Monitoring Combined with Computer-Based eMPC Algorithm for Tight Glucose Control in Cardiosurgical ICU

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F13%3A10194099" target="_blank" >RIV/00216208:11110/13:10194099 - isvavai.cz</a>

  • Alternative codes found

    RIV/00064165:_____/13:10194099

  • Result on the web

    <a href="http://dx.doi.org/10.1155/2013/186439" target="_blank" >http://dx.doi.org/10.1155/2013/186439</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1155/2013/186439" target="_blank" >10.1155/2013/186439</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The Use of Continuous Glucose Monitoring Combined with Computer-Based eMPC Algorithm for Tight Glucose Control in Cardiosurgical ICU

  • Original language description

    Aim. In postcardiac surgery patients, we assessed the performance of a system for intensive intravenous insulin therapy using continuous glucose monitoring (CGM) and enhanced model predictive control (eMPC) algorithm. Methods. Glucose control in eMPC-CGMgroup (n = 12) was compared with a control (C) group (n = 12) treated by intravenous insulin infusion adjusted according to eMPC protocol with a variable sampling interval alone. In the eMPC-CGM group glucose measured with a REAL-Time CGM system (Guardian RT) served as input for the eMPC adjusting insulin infusion every 15 minutes. The accuracy of CGM was evaluated hourly using reference arterial glucose and Clarke error-grid analysis (C-EGA). Target glucose range was 4.4-6.1mmol/L. Results. Of the 277paired CGM-reference glycemic values, 270 (97.5%) were in clinically acceptable zones of C-EGA and only 7 (2.5%) were in unacceptable D zone. Glucose control in eMPC-CGM group was comparable to C group in all measured values (average gly

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FP - Other medical fields

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    BioMed Research International

  • ISSN

    2314-6133

  • e-ISSN

  • Volume of the periodical

    Neuveden

  • Issue of the periodical within the volume

    Feb 20

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    8

  • Pages from-to

  • UT code for WoS article

    000315529200001