Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F17%3A10363400" target="_blank" >RIV/00216208:11110/17:10363400 - isvavai.cz</a>

  • Alternative codes found

    RIV/00064165:_____/17:10363400

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.nicl.2017.06.022" target="_blank" >http://dx.doi.org/10.1016/j.nicl.2017.06.022</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.nicl.2017.06.022" target="_blank" >10.1016/j.nicl.2017.06.022</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis

  • Original language description

    Background: There is a need for a brain volume measure applicable to the clinical routine scans. Nearly every multiple sclerosis (MS) protocol includes low-resolution 2D T2-FLAIR imaging. Objectives: To develop and validate cross-sectional and longitudinal brain atrophy measures on clinical-quality T2-FLAIR images in MS patients. Methods: A real-world dataset from 109 MS patients from 62 MRI scanners was used to develop a lateral ventricular volume (LVV) algorithm with a longitudinal Jacobian-based extension, called NeuroSTREAM. Goldstandard LVV was calculated on high-resolution T1 1 mm, while NeuroSTREAM LVV was obtained on lowresolution T2-FLAIR 3 mm thick images. Scan-rescan reliability was assessed in 5 subjects. The variability of LVV measurement at different field strengths was tested in 76 healthy controls and 125 MS patients who obtained both 1.5T and 3T scans in 72 hours. Clinical validation of algorithm was performed in 176 MS patients who obtained serial yearly MRI 1.5T scans for 10 years. Results: Correlation between gold-standard high-resolution T1 LVV and low-resolution T2-FLAIR LVV was r= 0.99, p &lt; 0.001 and the scan-rescan coefficient of variation was 0.84%. Correlation between low-resolution T2-FLAIR LVV on 1.5T and 3T was r= 0.99, p &lt; 0.001 and the scan-rescan coefficient of variation was 2.69% cross-sectionally and 2.08% via Jacobian integration. NeuroSTREAM showed comparable effect size (d = 0.39-0.71) in separating MS patients with and without confirmed disability progression, compared to SIENA and VIENA. Conclusions: Brain atrophy measurement on clinical quality T2-FLAIR scans is feasible, accurate, reliable, and relates to clinical outcomes

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30103 - Neurosciences (including psychophysiology)

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    NeuroImage: Clinical

  • ISSN

    2213-1582

  • e-ISSN

  • Volume of the periodical

    15

  • Issue of the periodical within the volume

    June

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    11

  • Pages from-to

    769-779

  • UT code for WoS article

    000410067200080

  • EID of the result in the Scopus database

    2-s2.0-85021448526