Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F17%3A10363400" target="_blank" >RIV/00216208:11110/17:10363400 - isvavai.cz</a>
Alternative codes found
RIV/00064165:_____/17:10363400
Result on the web
<a href="http://dx.doi.org/10.1016/j.nicl.2017.06.022" target="_blank" >http://dx.doi.org/10.1016/j.nicl.2017.06.022</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nicl.2017.06.022" target="_blank" >10.1016/j.nicl.2017.06.022</a>
Alternative languages
Result language
angličtina
Original language name
Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis
Original language description
Background: There is a need for a brain volume measure applicable to the clinical routine scans. Nearly every multiple sclerosis (MS) protocol includes low-resolution 2D T2-FLAIR imaging. Objectives: To develop and validate cross-sectional and longitudinal brain atrophy measures on clinical-quality T2-FLAIR images in MS patients. Methods: A real-world dataset from 109 MS patients from 62 MRI scanners was used to develop a lateral ventricular volume (LVV) algorithm with a longitudinal Jacobian-based extension, called NeuroSTREAM. Goldstandard LVV was calculated on high-resolution T1 1 mm, while NeuroSTREAM LVV was obtained on lowresolution T2-FLAIR 3 mm thick images. Scan-rescan reliability was assessed in 5 subjects. The variability of LVV measurement at different field strengths was tested in 76 healthy controls and 125 MS patients who obtained both 1.5T and 3T scans in 72 hours. Clinical validation of algorithm was performed in 176 MS patients who obtained serial yearly MRI 1.5T scans for 10 years. Results: Correlation between gold-standard high-resolution T1 LVV and low-resolution T2-FLAIR LVV was r= 0.99, p < 0.001 and the scan-rescan coefficient of variation was 0.84%. Correlation between low-resolution T2-FLAIR LVV on 1.5T and 3T was r= 0.99, p < 0.001 and the scan-rescan coefficient of variation was 2.69% cross-sectionally and 2.08% via Jacobian integration. NeuroSTREAM showed comparable effect size (d = 0.39-0.71) in separating MS patients with and without confirmed disability progression, compared to SIENA and VIENA. Conclusions: Brain atrophy measurement on clinical quality T2-FLAIR scans is feasible, accurate, reliable, and relates to clinical outcomes
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30103 - Neurosciences (including psychophysiology)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
NeuroImage: Clinical
ISSN
2213-1582
e-ISSN
—
Volume of the periodical
15
Issue of the periodical within the volume
June
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
11
Pages from-to
769-779
UT code for WoS article
000410067200080
EID of the result in the Scopus database
2-s2.0-85021448526