Evaluation of Timepix3 based CdTe photon counting detector for fully spectroscopic small animal SPECT imaging
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F18%3A10376267" target="_blank" >RIV/00216208:11110/18:10376267 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1088/1748-0221/13/01/C01001" target="_blank" >https://doi.org/10.1088/1748-0221/13/01/C01001</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/13/01/C01001" target="_blank" >10.1088/1748-0221/13/01/C01001</a>
Alternative languages
Result language
angličtina
Original language name
Evaluation of Timepix3 based CdTe photon counting detector for fully spectroscopic small animal SPECT imaging
Original language description
The imaging method of SPECT (Single Photon Emission Computed Tomography) is used in nuclear medicine for diagnostics of various diseases or organs malfunctions. The distribution of medically injected, inhaled, or ingested radionuclides (radiotracers) in the patient body is imaged using gamma-ray sensitive camera with suitable imaging collimator. The 3D image is then calculated by combining many images taken from different observation angles. Most of SPECT systems use scintillator based cameras. These cameras do not provide good energy resolution and do not allow efficient suppression of unwanted signals such as those caused by Compton scattering. The main goal of this work is evaluation of Timepix3 detector properties for SPECT method for functional imaging of small animals during preclinical studies. Advantageous Timepix3 properties such as energy and spatial resolution are exploited for significant image quality improvement. Preliminary measurements were performed on specially prepared plastic phantom with cavities filled by radioisotopes and then repeated with in vivo mouse sample.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Volume of the periodical
13
Issue of the periodical within the volume
January
Country of publishing house
GB - UNITED KINGDOM
Number of pages
10
Pages from-to
—
UT code for WoS article
000419048300001
EID of the result in the Scopus database
2-s2.0-85041803799