The repeatability of the instrumented timed Up & Go test: The performance of older adults and parkinson's disease patients under different conditions
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10405728" target="_blank" >RIV/00216208:11110/20:10405728 - isvavai.cz</a>
Alternative codes found
RIV/00064165:_____/20:10405728 RIV/00216208:11310/20:10405728 RIV/68407700:21460/20:00336091
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=KgezGNc0i0" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=KgezGNc0i0</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.bbe.2019.12.001" target="_blank" >10.1016/j.bbe.2019.12.001</a>
Alternative languages
Result language
angličtina
Original language name
The repeatability of the instrumented timed Up & Go test: The performance of older adults and parkinson's disease patients under different conditions
Original language description
The Timed Up & Go (TUG) test is a simple test for gait and balance that requires no special equipment and can be part of a routine clinical examination. Combined with the development of motion capture technologies, the possibilities of assessing individual TUG sub-components (i.e. sit-to-stand, gait, turn, turn-to-sit) are increasing. The clinical evaluation of an instrumented TUG requires reliable values. We analysed the intra-session repeatability of the iTUG sit-to-stand, gait and turn parameters in three conditions: (1) single, (2) cognitive dual-tasks, and (3) manual dual-tasks in older adults and Parkinson's disease (PD) patients. The repeatability coefficient (RC) was calculated for each of the 18 parameters. The repeatability varied across subject groups, the performed tasks, and the TUG subcomponent. The gait subcomponent had 6 non-repeatable spatio-temporal parameters and 2 non-repeatable parameters for the arm swing. The parameters of the turn subcomponent can be considered as non-repeatable in both groups under the manual dual-task condition and in HC under the single-task condition. When comparing PD to HC, the repeatability of the majority of the single-task parameters was higher in PD whereas lower under dual-tasks. In PD, the major part of gait parameters had a higher repeatability under single-tasks than dual-tasks. In contrast, HC exhibited better repeatability of dual-tasks than single-tasks. Repeatability can be used to assist researchers and clinicians to select adequate parameters with respect to the purpose of motion assessment.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30103 - Neurosciences (including psychophysiology)
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Biocybernetics and Biomedical Engineering
ISSN
0208-5216
e-ISSN
—
Volume of the periodical
40
Issue of the periodical within the volume
1
Country of publishing house
PL - POLAND
Number of pages
15
Pages from-to
363-377
UT code for WoS article
000528800500028
EID of the result in the Scopus database
2-s2.0-85077916021