Sensitive CE-MS method for monitoring of riociguat and desmethylriociguat levels in human serum

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10413160" target="_blank" >RIV/00216208:11110/20:10413160 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11120/20:43920284 RIV/00216208:11310/20:10413160 RIV/00216275:25310/20:39916190 RIV/00064165:_____/20:10413160

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Xim-qvslNn" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Xim-qvslNn</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/elps.202000135" target="_blank" >10.1002/elps.202000135</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Sensitive CE-MS method for monitoring of riociguat and desmethylriociguat levels in human serum

  • Original language description

    Riociguat is novel antihypertensive drug for treatment of pulmonary hypertension. As such, it is still being tested in many clinical and pharmacokinetic trials. Existing methods that determine serum riociguat and desmethylriociguat (DMR) are based solely on liquid chromatography with mass spectrometry. Therefore, we present a novel capillary electrophoresis with mass spectrometry method (CE-MS) for their determination in human serum as alternative method for ongoing trials. Complete resolution of both analytes was achieved by means of pH optimization of ammonium formate background electrolytes that are fully compatible with ESI/MS detection. Simple liquid-liquid extraction was used as sample pretreatment. The calibration dependence of the method was linear (in the range of 10-1000 ng/mL), with adequate accuracy (90.1-114.9%) and precision (13.4%). LOD and LOQ were arbitrarily set at 10 ng/mL for both analytes. Clinical applicability was validated using serum samples from patients treated with riociguat in pharmacokinetic study and the results corresponded with reference HPLC-MS/MS values. Capillary electrophoresis proved to be sensitive and selective tool for the analysis of riociguat and DMR.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Electrophoresis

  • ISSN

    0173-0835

  • e-ISSN

  • Volume of the periodical

    41

  • Issue of the periodical within the volume

    18-19

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    4

  • Pages from-to

    1564-1567

  • UT code for WoS article

    000554033200001

  • EID of the result in the Scopus database

    2-s2.0-85089146202