Pressure and flow properties of dual-lumen cannulae for extracorporeal membrane oxygenation

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10418518" target="_blank" >RIV/00216208:11110/20:10418518 - isvavai.cz</a>

  • Alternative codes found

    RIV/00064165:_____/20:10418518

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=vsL.uGMmqc" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=vsL.uGMmqc</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1177/0267659120926009" target="_blank" >10.1177/0267659120926009</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Pressure and flow properties of dual-lumen cannulae for extracorporeal membrane oxygenation

  • Original language description

    Introduction: In the last decade, dual-lumen cannulae have been increasingly applied in patients undergoing extracorporeal life support. Well-performing vascular access is crucial for efficient extracorporeal membrane oxygenation support; thus, guidance for proper cannulae size is required. Pressure-flow charts provided by manufacturers are often based on tests performed using water, rarely blood. However, blood is a shear-thinning and viscoelastic fluid characterized by different flow properties than water. Methods: We performed a study evaluating pressure-flow curves during standardized conditions using human whole blood in two commonly available dual-lumen cannulae used in neonates, pediatric, and adult patients. Results were merged and compared with the manufacturer&apos;s corresponding curves obtained from the public domain. Results: The results showed that using blood as compared with water predominantly influenced drainage flow. A 10-80% higher pressure-drop was needed to obtain same drainage flow (hematocrit of 26%) compared with manufacturer&apos;s water charts in 13-31 Fr bi-caval dual-lumen cannulae. The same net difference was found in cavo-atrial cannulae (16-32 Fr), where a lower drainage pressure was required (Hct of 26%) compared with the manufacturer&apos;s test using blood with an Hct of 33%. Return pressure-flow data were similar, independent whether pumping blood or water, to the data reported by manufacturers. Conclusion: Non-standardized testing of pressure-flow properties of extracorporeal membrane oxygenation dual-lumen cannulae prevents an adequate prediction of pressure-flow results when these cannulae are used in patients. Properties of dual-lumen cannulae may vary between sizes within same cannula family, in particular concerning the drainage flow.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Perfusion

  • ISSN

    0267-6591

  • e-ISSN

  • Volume of the periodical

    35

  • Issue of the periodical within the volume

    8

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    9

  • Pages from-to

    736-744

  • UT code for WoS article

    000538270300001

  • EID of the result in the Scopus database

    2-s2.0-85085931366