Decrease in hand and cerebral oxygenation after percutaneous transluminal angioplasty for arteriovenous fistula stenosis in a patient on chronic hemodialysis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11110%2F20%3A10423507" target="_blank" >RIV/00216208:11110/20:10423507 - isvavai.cz</a>
Alternative codes found
RIV/00064165:_____/20:10423507
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=gT2bGFqJsQ" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=gT2bGFqJsQ</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radcr.2020.05.072" target="_blank" >10.1016/j.radcr.2020.05.072</a>
Alternative languages
Result language
angličtina
Original language name
Decrease in hand and cerebral oxygenation after percutaneous transluminal angioplasty for arteriovenous fistula stenosis in a patient on chronic hemodialysis
Original language description
A 79-year-old woman who was on chronic hemodialysis due to diabetic nephropathy and had previously undergo surgery for radiocephalic arteriovenous fistula (AVF) in her right wrist needed percutaneous transluminal angioplasty (PTA) for stenosis at the juxta-anastomotic access site. After successful PTA, the systemic blood pressure decreased from 144/93 mm Hg to 117/67 mm Hg in response to the increase in AVF blood flow. Furthermore, the regional oxygen saturation (rSO2) value in her dorsal hand decreased from 67.9% to 64.9% and, simultaneously, the cerebral rSO2 decreased from 63.6% to 60.1%. Our experience indicates that the PTA procedure may affect the rapid deterioration of systemic oxygenation, including that in the hand and brain, in association with the increase in the AVF blood flow and change in systemic circulation.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Radiology Case Reports
ISSN
1930-0433
e-ISSN
—
Volume of the periodical
15
Issue of the periodical within the volume
9
Country of publishing house
US - UNITED STATES
Number of pages
3
Pages from-to
1493-1495
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-85087354111