All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Very fast electrophoretic determination of creatinine and uric acid in human urine using a combination of two capillaries with different internal diameters

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F14%3A43907632" target="_blank" >RIV/00216208:11120/14:43907632 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1002/elps.201300293" target="_blank" >http://dx.doi.org/10.1002/elps.201300293</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/elps.201300293" target="_blank" >10.1002/elps.201300293</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Very fast electrophoretic determination of creatinine and uric acid in human urine using a combination of two capillaries with different internal diameters

  • Original language description

    A capillary system formed by combining 25 ?m and 100 ?m id capillaries was used in the short-end injection mode to determine creatinine and uric acid in human urine. The separation was performed at an electric field intensity of 2.3 kV/cm. Creatinine wasdetermined in a background electrolyte with a composition of 20 mM citric acid/NaOH (pH 3.0) and uric acid was determined in 20 mM MES/NaOH (pH 6.0). Under these conditions, migration times of 12.2 s for creatinine and 8.6 s for uric acid were achieved.The LOD value is 2.4 mg/L for creatinine and 0.9 mg/L for uric acid; the RSD for the migration time varies in the range 0.7-1.1% (intra day) to 1.0-7.5% (inter day); RSDs for the peak areas equalled 3.4-4.0% (intra day) and 4.3-4.7% (inter day). The determined creatinine values in 7 urine samples vary in the range 221-1394 mg/L for creatinine and 87-615 mg/L for uric acid. T-test did not reveal any statistically significant difference between the developed CE methodologies and reference

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CG - Electrochemistry

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/GAP206%2F11%2F0707" target="_blank" >GAP206/11/0707: Voltammetric assessment of new ionic liquids for their applications in capillary electrophoresis</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Electrophoresis

  • ISSN

    0173-0835

  • e-ISSN

  • Volume of the periodical

    35

  • Issue of the periodical within the volume

    7

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    6

  • Pages from-to

    956-961

  • UT code for WoS article

    000333644600004

  • EID of the result in the Scopus database