All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Absorb bioresorbable stents for the treatment of coronary artery disease

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F15%3A43910235" target="_blank" >RIV/00216208:11120/15:43910235 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1586/17434440.2015.1080119" target="_blank" >http://dx.doi.org/10.1586/17434440.2015.1080119</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1586/17434440.2015.1080119" target="_blank" >10.1586/17434440.2015.1080119</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Absorb bioresorbable stents for the treatment of coronary artery disease

  • Original language description

    Bioresorbable stents are considered to be the 'fourth revolution' in percutaneous coronary intervention. The first clinically available Absorb((R)) bioresorbable device is made of poly-l-lactic acid polymer and elutes everolimus. The process of bioresorption is completed in 3 years. The introduction of this device into clinical practice went through several logical phases: first-in-man studies, randomized Absorb II study with moderately complex patients and lesions, registries of real life patient population and reports of challenging cases. The procedural results are excellent; many insights have been gained by intracoronary imaging. Intermediate-term outcomes are very encouraging both from imaging and from clinical perspectives. The issue of increased stent thrombosis rate was raised in one study, but other studies have been reassuring. Excellent lesion preparation, sizing and complete expansion of the Absorb device are crucial for optimal procedural and clinical results. Results of

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FA - Cardiovascular diseases including cardio-surgery

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Expert Review of Medical Devices

  • ISSN

    1743-4440

  • e-ISSN

  • Volume of the periodical

    12

  • Issue of the periodical within the volume

    5

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    13

  • Pages from-to

    545-557

  • UT code for WoS article

    000360296900007

  • EID of the result in the Scopus database