All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Frequency-tuned contactless conductivity detector for the electrophoretic separation of clinical samples in capillaries with very small internal dimensions

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F17%3A43912635" target="_blank" >RIV/00216208:11120/17:43912635 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1002/jssc.201601213" target="_blank" >http://dx.doi.org/10.1002/jssc.201601213</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/jssc.201601213" target="_blank" >10.1002/jssc.201601213</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Frequency-tuned contactless conductivity detector for the electrophoretic separation of clinical samples in capillaries with very small internal dimensions

  • Original language description

    An axial design of a capacitively coupled contactless conductivity detector was tested in combination with fused silica capillaries with internal diameters of 10, 15 and 25 μm, which are used for high-efficiency electrophoretic separation. The transmission of the signal in the detection probe dependent on the specific conductivity of the solution in the capillary in the range 0-278 mS.m(-1) has a complex character and a minimum appears on the curve at very low conductivities. The position of the minimum of the calibration dependence gradually shifts with decreasing frequency of the exciting signal from 1.0 to 0.25 MHz towards lower specific conductivity values. The presence of a minimum on the calibration curves is a natural property of the axial design of contactless conductivity detector, demonstrated by solution of the equivalent electrical circuit of the detection probe, and is specifically caused by the use of shielding foil. The behavior of contactless conductivity detector in the vicinity of the minimum was documented for practical separations of amino acids in solutions of 3.2 M acetic acid with addition of 0-50% v/v methanol.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    <a href="/en/project/GA15-03139S" target="_blank" >GA15-03139S: New Electrophoretic Approaches in Studies of Obesity and Diabetes</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Separation Science

  • ISSN

    1615-9306

  • e-ISSN

  • Volume of the periodical

    40

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    8

  • Pages from-to

    940-947

  • UT code for WoS article

    000397828000015

  • EID of the result in the Scopus database

    2-s2.0-85013270025