Contact less Conductivity Detection in Capillary Electrophoresis Employing Capillaries with Very Low Inner Diameters
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F11%3A10104446" target="_blank" >RIV/00216208:11310/11:10104446 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11120/11:00003217
Result on the web
<a href="http://dx.doi.org/10.1002/elan.201100264" target="_blank" >http://dx.doi.org/10.1002/elan.201100264</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elan.201100264" target="_blank" >10.1002/elan.201100264</a>
Alternative languages
Result language
angličtina
Original language name
Contact less Conductivity Detection in Capillary Electrophoresis Employing Capillaries with Very Low Inner Diameters
Original language description
The behaviour of a contactless conductivity detector was studied in its application to capillary electrophoresis employing quartz capillaries with inner diameters (i.d.) of 10 to 75 inn. The detector output signal was measured using KCl as the test electrolyte, within a KCl concentration range from 0 to 100 mmol/L, corresponding to specific conductivities from 0 to 1295 mS/m. When using capillaries with high inner diameters, then the signal-to-noise ratio is high in electrolytes of low conductivity. Onthe other hand, the use of capillaries with low i.d. values is useful in separations employing solutions of high conductivities. The advantages of capillaries with small i.d. values, combined with contactless conductivity detection, are demonstrated on separations of mixtures of inorganic ions and on Separations of neutral mono- and disaccharides.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GAP206%2F10%2F1231" target="_blank" >GAP206/10/1231: New Electrophoretic Approaches to the Monitoring of Pain Neurotransmitters in the Brain Tissue of Higher Organisms</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2011
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Volume of the periodical
23
Issue of the periodical within the volume
8
Country of publishing house
DE - GERMANY
Number of pages
5
Pages from-to
1870-1874
UT code for WoS article
000294037300015
EID of the result in the Scopus database
—