All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Contact less Conductivity Detection in Capillary Electrophoresis Employing Capillaries with Very Low Inner Diameters

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11310%2F11%3A10104446" target="_blank" >RIV/00216208:11310/11:10104446 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11120/11:00003217

  • Result on the web

    <a href="http://dx.doi.org/10.1002/elan.201100264" target="_blank" >http://dx.doi.org/10.1002/elan.201100264</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/elan.201100264" target="_blank" >10.1002/elan.201100264</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Contact less Conductivity Detection in Capillary Electrophoresis Employing Capillaries with Very Low Inner Diameters

  • Original language description

    The behaviour of a contactless conductivity detector was studied in its application to capillary electrophoresis employing quartz capillaries with inner diameters (i.d.) of 10 to 75 inn. The detector output signal was measured using KCl as the test electrolyte, within a KCl concentration range from 0 to 100 mmol/L, corresponding to specific conductivities from 0 to 1295 mS/m. When using capillaries with high inner diameters, then the signal-to-noise ratio is high in electrolytes of low conductivity. Onthe other hand, the use of capillaries with low i.d. values is useful in separations employing solutions of high conductivities. The advantages of capillaries with small i.d. values, combined with contactless conductivity detection, are demonstrated on separations of mixtures of inorganic ions and on Separations of neutral mono- and disaccharides.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/GAP206%2F10%2F1231" target="_blank" >GAP206/10/1231: New Electrophoretic Approaches to the Monitoring of Pain Neurotransmitters in the Brain Tissue of Higher Organisms</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2011

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Electroanalysis

  • ISSN

    1040-0397

  • e-ISSN

  • Volume of the periodical

    23

  • Issue of the periodical within the volume

    8

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    5

  • Pages from-to

    1870-1874

  • UT code for WoS article

    000294037300015

  • EID of the result in the Scopus database