All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Rapid and Sensitive Determination of Branched-Chain Amino Acids in Human Plasma by Capillary Electrophoresis with Contactless Conductivity Detection for Physiological Studies

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F19%3A43917764" target="_blank" >RIV/00216208:11120/19:43917764 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1007/978-1-4939-9213-3_2" target="_blank" >https://doi.org/10.1007/978-1-4939-9213-3_2</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/978-1-4939-9213-3_2" target="_blank" >10.1007/978-1-4939-9213-3_2</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Rapid and Sensitive Determination of Branched-Chain Amino Acids in Human Plasma by Capillary Electrophoresis with Contactless Conductivity Detection for Physiological Studies

  • Original language description

    Capillary electrophoresis (CE) with contactless conductivity detection (C 4 D) represents a strong tool for determining amino acids in clinical samples. This chapter provides detailed instructions for CE/C 4 D determination of the branched-chain amino acids (BCAAs) valine, isoleucine, and leucine in human plasma, which can be readily employed in physiological studies. Baseline separation of all the BCAAs is achieved on a short separation length equal to 18 cm in optimized background electrolyte consisting of 3.2 M acetic acid dissolved in 20% v/v methanol with addition of 1.0% v/v INST-coating solution. The analysis time does not exceed 3 min and the limit of detection is 0.4 μM for all BCAAs. The pretreatment of human plasma is very simple and is based on fourfold plasma dilution by acetonitrile and subsequent filtration. Only 50 μL of plasma is used for the analysis. The high sensitivity of the CE/C 4 D method is achieved by injecting a large volume of sample, combined with application of negative pressure to flush the acetonitrile zone out of the capillary.

  • Czech name

  • Czech description

Classification

  • Type

    C - Chapter in a specialist book

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    <a href="/en/project/GA18-04902S" target="_blank" >GA18-04902S: Instrumentation for continuous on-line electtrophoretic monitoring of metabolic processes in living organisms</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Book/collection name

    Clinical Applications of Capillary Electrophoresis: Methods and Protocols

  • ISBN

    978-1-4939-9212-6

  • Number of pages of the result

    10

  • Pages from-to

    15-24

  • Number of pages of the book

    273

  • Publisher name

    Humana Press

  • Place of publication

    New York

  • UT code for WoS chapter