All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Dialysis of one sample drop on-line connected with electrophoresis in short capillary

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F20%3A43920261" target="_blank" >RIV/00216208:11120/20:43920261 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11310/20:10413172

  • Result on the web

    <a href="https://doi.org/10.1016/j.talanta.2020.121252" target="_blank" >https://doi.org/10.1016/j.talanta.2020.121252</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.talanta.2020.121252" target="_blank" >10.1016/j.talanta.2020.121252</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Dialysis of one sample drop on-line connected with electrophoresis in short capillary

  • Original language description

    An analytical apparatus is described, based on on-line connection of electrophoresis in a short capillary with a dialysis unit enabling dialysis in micro-litre sample volumes into submicro-litre volumes of an acceptor solution in a dialysing fibre. After a defined dialysis time, the dialysate from the dialysing fibre is injected into a separation capillary through an air-assisted flow-gating interface cast from PDMS. In the flow-gating injection space, the exit from the delivery capillary bringing the dialysate is placed directly opposite the entrance into the separation capillary at a distance of 380 μm. In order to enable injection of a very small volume of dialysate, the background electrolyte is forced out of the injection space with air before the injection, so that a drop of dialysate with a volume of about 0.1 μL is formed between the exit from the delivery and the entrance into the separation capillary; the dialysate is injected hydrodynamically from this dialysate drop. Then the injection space is filled with the background electrolyte and the separation is commenced. The basic properties of the apparatus were tested on model mixtures of inorganic cations (K+, Ba2+ and Na+) and organic molecules (creatinine, histidine and arginine). The applicability to real samples was tested on the determination of basic amino acids (histidine, lysine and arginine) in a blood serum sample.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    <a href="/en/project/GA18-04902S" target="_blank" >GA18-04902S: Instrumentation for continuous on-line electtrophoretic monitoring of metabolic processes in living organisms</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Talanta

  • ISSN

    0039-9140

  • e-ISSN

  • Volume of the periodical

    219

  • Issue of the periodical within the volume

    November

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    7

  • Pages from-to

    "Article 121252"

  • UT code for WoS article

    000568744000002

  • EID of the result in the Scopus database

    2-s2.0-85086641814