Dialysis of one sample drop on-line connected with electrophoresis in short capillary
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F20%3A43920261" target="_blank" >RIV/00216208:11120/20:43920261 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11310/20:10413172
Result on the web
<a href="https://doi.org/10.1016/j.talanta.2020.121252" target="_blank" >https://doi.org/10.1016/j.talanta.2020.121252</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2020.121252" target="_blank" >10.1016/j.talanta.2020.121252</a>
Alternative languages
Result language
angličtina
Original language name
Dialysis of one sample drop on-line connected with electrophoresis in short capillary
Original language description
An analytical apparatus is described, based on on-line connection of electrophoresis in a short capillary with a dialysis unit enabling dialysis in micro-litre sample volumes into submicro-litre volumes of an acceptor solution in a dialysing fibre. After a defined dialysis time, the dialysate from the dialysing fibre is injected into a separation capillary through an air-assisted flow-gating interface cast from PDMS. In the flow-gating injection space, the exit from the delivery capillary bringing the dialysate is placed directly opposite the entrance into the separation capillary at a distance of 380 μm. In order to enable injection of a very small volume of dialysate, the background electrolyte is forced out of the injection space with air before the injection, so that a drop of dialysate with a volume of about 0.1 μL is formed between the exit from the delivery and the entrance into the separation capillary; the dialysate is injected hydrodynamically from this dialysate drop. Then the injection space is filled with the background electrolyte and the separation is commenced. The basic properties of the apparatus were tested on model mixtures of inorganic cations (K+, Ba2+ and Na+) and organic molecules (creatinine, histidine and arginine). The applicability to real samples was tested on the determination of basic amino acids (histidine, lysine and arginine) in a blood serum sample.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
<a href="/en/project/GA18-04902S" target="_blank" >GA18-04902S: Instrumentation for continuous on-line electtrophoretic monitoring of metabolic processes in living organisms</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Talanta
ISSN
0039-9140
e-ISSN
—
Volume of the periodical
219
Issue of the periodical within the volume
November
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
7
Pages from-to
"Article 121252"
UT code for WoS article
000568744000002
EID of the result in the Scopus database
2-s2.0-85086641814