All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

A new electromembrane extraction probe for on-line connection with capillary electrophoresis for determination of substances in biological matrices

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11120%2F23%3A43924371" target="_blank" >RIV/00216208:11120/23:43924371 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11310/23:10451191

  • Result on the web

    <a href="https://doi.org/10.1016/j.talanta.2022.124149" target="_blank" >https://doi.org/10.1016/j.talanta.2022.124149</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.talanta.2022.124149" target="_blank" >10.1016/j.talanta.2022.124149</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    A new electromembrane extraction probe for on-line connection with capillary electrophoresis for determination of substances in biological matrices

  • Original language description

    A miniature probe for electromembrane extraction is developed and constructed. The tubular probe with an internal volume of 1.1 μL is made of polypropylene hollow fiber with a supported liquid membrane of 85% nitrophenyloctyl ether (NPOE) with 15% bis(2-ethylhexyl)phosphonic acid (DEHP). The probe is connected on-line to the electrophoresis with short separation capillary via an air assisted flow gating interface cast from poly (dimethylsiloxane). The compact instrument is computer controlled via LabView. The probe parameters are tested for extraction of creatinine and basic amino acids from artificial solution and human urine. The sensitivity of the electrophoretic determination after 300 s extraction at 150 V compared to the sensitivity without extraction is 4.9-fold and 2.6-fold higher for creatinine and arginine, respectively. The RSDs for peak area measured from 5 repeated extractions of 50 μM solutions are 7.5%, 7.2%, 8.6% and 9.2% for Crea, Lys, Arg and His, respectively. The probe can be used for all-day measurements. The preparation of the probe is simple and requires no special tool.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    <a href="/en/project/GA22-22398S" target="_blank" >GA22-22398S: Microfluidic and electronic devices for on-line electrophoretic analysis of adipose tissue</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Talanta

  • ISSN

    0039-9140

  • e-ISSN

    1873-3573

  • Volume of the periodical

    254

  • Issue of the periodical within the volume

    March

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    5

  • Pages from-to

    124149

  • UT code for WoS article

    001003492200003

  • EID of the result in the Scopus database

    2-s2.0-85143527215