All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Mechanical testing of newly developed biomaterial designed for intra-articular reinforcement of partially ruptured cranial cruciate ligament: ex vivo pig model

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F14%3A10292716" target="_blank" >RIV/00216208:11130/14:10292716 - isvavai.cz</a>

  • Alternative codes found

    RIV/62157124:16170/14:43872758 RIV/62157124:16810/14:43872758 RIV/00216305:26110/14:PU108593

  • Result on the web

    <a href="http://dx.doi.org/10.2754/avb201483010055" target="_blank" >http://dx.doi.org/10.2754/avb201483010055</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.2754/avb201483010055" target="_blank" >10.2754/avb201483010055</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Mechanical testing of newly developed biomaterial designed for intra-articular reinforcement of partially ruptured cranial cruciate ligament: ex vivo pig model

  • Original language description

    The study deals with mechanical testing of newly developed material polyethylene terephtalate coated with polycaprolactone nanofibers in combination with biodagradable Hexalon ACL/PCL screws as a new possibility of intra-articular reinforcement of partially ruptured cranial cruciate ligament. Four groups of ex vivo models of pig stifle joints were prepared and tested: a model with intact CCL (group 1), a model with partial CCL rupture (group 2), a model with CCL rupture stabilized with 7 mm Mersilene strip (group 3), and a model with CCL rupture stabilized with 5 mm PET/PCL biomaterial strip (group 4). The models were loaded in the standing angle of 1000 and the maximum load (N) and the shift (mm) were monitored. The mean maximum peak power and the shift were 1266.0 +/- 146.9 N and 13.7 +/- 2.5 mm for group 1, and 1164.7 +/- 228.2 N and 1 6.8 +/- 3.3 mm for group 2, respectively. In all cases after reaching the maximum load, a tibial fracture occurred but never a CCL rupture. In groups

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    GJ - Diseases and animal vermin, veterinary medicine

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/ED1.1.00%2F02.0068" target="_blank" >ED1.1.00/02.0068: Central european institute of technology</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Acta Veterinaria Brno

  • ISSN

    0001-7213

  • e-ISSN

  • Volume of the periodical

    83

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    6

  • Pages from-to

    55-60

  • UT code for WoS article

    000335204700010

  • EID of the result in the Scopus database