Intra-Articular Reinforcement of a Partially Torn Anterior Cruciate Ligament (ACL) Using Newly Developed UHMWPE Biomaterial in Combination with Hexalon ACL/PCL Screws: Ex-vivo Mechanical Testing of an Animal Knee Model

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16170%2F15%3A43873662" target="_blank" >RIV/62157124:16170/15:43873662 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Intra-Articular Reinforcement of a Partially Torn Anterior Cruciate Ligament (ACL) Using Newly Developed UHMWPE Biomaterial in Combination with Hexalon ACL/PCL Screws: Ex-vivo Mechanical Testing of an Animal Knee Model

  • Original language description

    Recent trends in the experimental surgical management of a partial anterior cruciate ligament (ACL) rupture in animals show repair of an ACL lesion using novel biomaterials both for biomechanical reinforcement of a partially unstable knee and as suitablescaffolds for bone marrow stem cell therapy in a partial ACL tear. The study deals with mechanical testing of the newly developed ultra-high-molecular-weight polyethylene (UHMWPE) biomaterial anchored to bone with Hexalon biodegradable ACL/PCL screws, as a new possibility of intra-articular reinforcement of a partial ACL tear. Two groups of ex vivo pig knee models were prepared and tested as follows: the model of an ACL tear stabilised with UHMWPE biomaterial using a Hexalon ACL/PCL screw (group 1; n =10) and the model of an ACL tear stabilised with the traditional, and in veterinary medicine used, extracapsular technique involving a monofilament nylon fibre, a clamp and a Securos bone anchor (group 2; n = 11). The models were loaded

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FP - Other medical fields

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Acta Chirurgiae Orthopaedicae et Traumatologiae Cechoslovaca

  • ISSN

    0001-5415

  • e-ISSN

  • Volume of the periodical

    82

  • Issue of the periodical within the volume

    3

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    7

  • Pages from-to

    222-228

  • UT code for WoS article

    000358028700008