A Comparison of Four Methods (Immunochemistry and HPLC) for Determination of 25-(OH)-Vitamin D in Postmenopausal Women
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F17%3A10373908" target="_blank" >RIV/00216208:11130/17:10373908 - isvavai.cz</a>
Alternative codes found
RIV/00064203:_____/17:10373908
Result on the web
<a href="https://doi.org/10.7754/Clin.Lab.2016.160509" target="_blank" >https://doi.org/10.7754/Clin.Lab.2016.160509</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.7754/Clin.Lab.2016.160509" target="_blank" >10.7754/Clin.Lab.2016.160509</a>
Alternative languages
Result language
angličtina
Original language name
A Comparison of Four Methods (Immunochemistry and HPLC) for Determination of 25-(OH)-Vitamin D in Postmenopausal Women
Original language description
Background: Three immunochemical methods for the determination of 25-(OH)-vitamin D and validated HPLC method for the determination of 25-(OH)-vitamin D3 and 25-(OH)-vitamin D2 were compared. 62 patient samples from postmenopausal women were measured and the results obtained by all these methods were compared. Methods: We used three chemiluminescent assays for determination of 25-(OH)-vitamin D. 25-(OH)-vitamin D3 and 25-(OH)-vitamin Dy were determined by HPLC with UV detection (Agilent 1200). The chemiluminescent assays were performed using the Abbott Architect i4000SR analyzer (Abbott Laboratories, Germany), the ADVIA Centaur (Siemens, USA), and the Liaison XL (DiaSorin Inc, USA). The statistical evaluation was done using GraphPad Prism 6.0. Results: The data were tested by Tukey's multiple comparison test. All methods showed significant differences in comparison with the immunochemical method from DiaSorin (p < 0.001 for Abbott, p < 0.05 for Siemens, and p < 0.0001 for HPLC). The comparison of the immunochemical method from Siemens with HPLC was also significant, p < 0.05. The mean of DiaSorin measurements was 38% lower than the mean of HPLC measurements. The non-significant difference was shown by the comparison of Abbott with HPLC and also Abbott with Siemens. Means for the 25-(OH)-vitamin D methods used were: Abbott 70.2 +/- 24.2 nmoUL, Siemens 67.6 +/- 27.9 nmol/L, DiaSorin 53.5 +/- 17.1, and HPLC 82.4 +/- 40.0 nmol/L. Conclusions: The comparison of the DiaSorin immunochemical assay with other tested methods showed the greatest deviation. The mean of DiaSorin measurements was 38% lower than the mean of HPLC measurements. According to the results of the DiaSorin method, most patients treated with vitamin D would not achieve the optimal level of 25-(OH)-vitamin D and this could negatively affect the clinical decision.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10608 - Biochemistry and molecular biology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Clinical Laboratory
ISSN
1433-6510
e-ISSN
—
Volume of the periodical
63
Issue of the periodical within the volume
2
Country of publishing house
DE - GERMANY
Number of pages
4
Pages from-to
385-388
UT code for WoS article
000394483800024