A comparative analysis of imaging-based algorithms for detecting focal cortical dysplasia type II in children
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11130%2F25%3A10500483" target="_blank" >RIV/00216208:11130/25:10500483 - isvavai.cz</a>
Alternative codes found
RIV/00064203:_____/25:10500483
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=fAh~Dv5PaG" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=fAh~Dv5PaG</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41598-025-16015-3" target="_blank" >10.1038/s41598-025-16015-3</a>
Alternative languages
Result language
angličtina
Original language name
A comparative analysis of imaging-based algorithms for detecting focal cortical dysplasia type II in children
Original language description
Focal cortical dysplasia (FCD) is the leading cause of drug-resistant epilepsy (DRE) in pediatric patients. Accurate detection of FCDs is crucial for successful surgical outcomes, yet remains challenging due to frequently subtle MRI findings, especially in children, whose brain morphology undergoes significant developmental changes. Automated detection algorithms have the potential to improve diagnostic precision, particularly in cases, where standard visual assessment fails. This study aimed to evaluate the performance of automated algorithms in detecting FCD type II in pediatric patients and to examine the impact of adult versus pediatric templates on detection accuracy. MRI data from 23 surgical pediatric patients with histologically confirmed FCD type II were retrospectively analyzed. Three imaging-based detection algorithms were applied to T1-weighted images, each targeting key structural features: cortical thickness, gray matter intensity (extension), and gray-white matter junction blurring. Their performance was assessed using adult and pediatric healthy controls templates, with validation against both predictive radiological ROIs (PRR) and post-resection cavities (PRC). The junction algorithm achieved the highest median dice score (0.028, IQR 0.038, p < 0.01 when compared with other algorithms) and detected relevant clusters even in MRI-negative cases. The adult template (median dice score 0.013, IQR 0.027) significantly outperformed the pediatric template (0.0032, IQR 0.023) (p < 0.001), highlighting the importance of template consistency. Despite superior performance of the adult template, its use in pediatric populations may introduce bias, as it does not account for age-specific morphological features such as cortical maturation and incomplete myelination. Automated algorithms, especially those targeting junction blurring, enhance FCD detection in pediatric populations. These algorithms may serve as valuable decision-support tools, particularly in settings where neuroradiological expertise is limited.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30103 - Neurosciences (including psychophysiology)
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Scientific Reports
ISSN
2045-2322
e-ISSN
2045-2322
Volume of the periodical
15
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
15
Pages from-to
29946
UT code for WoS article
001551657500012
EID of the result in the Scopus database
2-s2.0-105013253498