Vascular histopathologic reaction to pulmonary artery banding in an in vivo growing porcine model
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11140%2F13%3A10139586" target="_blank" >RIV/00216208:11140/13:10139586 - isvavai.cz</a>
Result on the web
<a href="http://link.springer.com/article/10.1007%2Fs00246-013-0699-z" target="_blank" >http://link.springer.com/article/10.1007%2Fs00246-013-0699-z</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00246-013-0699-z" target="_blank" >10.1007/s00246-013-0699-z</a>
Alternative languages
Result language
angličtina
Original language name
Vascular histopathologic reaction to pulmonary artery banding in an in vivo growing porcine model
Original language description
Pulmonary artery banding (PAB) is used as a surgical palliation to reduce excessive pulmonary blood flow caused by congenital heart defects. Due to the lack of microscopic studies dealing with the tissue remodeling caused by contemporary PAB materials, this study aimed to assess histologic changes associated with PAB surgery by analyzing local tissue reaction to the presence of Gore-Tex strips fixed around the pulmonary artery. Gore-Tex strips were used for PAB in a growing porcine model. After 5 weeks,histologic samples with PAB (n = 5) were compared with healthy pulmonary arterial segments distal to the PAB or from a sham-treated animal (n = 1). Stereology was used to quantify the density of the vasa vasorum and the area fraction of elastin, smoothmuscle actin, macrophages, and nervi vasorum within the pulmonary arterial wall. The null hypothesis stated that samples did not differ histopathologically from adjacent vascular segments or sham-treated samples. The PAB samples had a gre
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
EA - Morphology and cytology
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/ED2.1.00%2F03.0076" target="_blank" >ED2.1.00/03.0076: Biomedical Centre of the Faculty of Medicine in Pilsen</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Pediatric Cardiology
ISSN
0172-0643
e-ISSN
—
Volume of the periodical
34
Issue of the periodical within the volume
7
Country of publishing house
US - UNITED STATES
Number of pages
9
Pages from-to
1652-1660
UT code for WoS article
000324638500016