Dual-phase dual-energy CT in patients with lung cancer: assessment of the additional value of iodine quantification in lymph node therapy response
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11140%2F14%3A10218694" target="_blank" >RIV/00216208:11140/14:10218694 - isvavai.cz</a>
Alternative codes found
RIV/00669806:_____/14:10218694
Result on the web
<a href="http://link.springer.com/article/10.1007%2Fs00330-014-3223-9" target="_blank" >http://link.springer.com/article/10.1007%2Fs00330-014-3223-9</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00330-014-3223-9" target="_blank" >10.1007/s00330-014-3223-9</a>
Alternative languages
Result language
angličtina
Original language name
Dual-phase dual-energy CT in patients with lung cancer: assessment of the additional value of iodine quantification in lymph node therapy response
Original language description
To investigate the potential contribution of iodine uptake calculation from dual-phase dual-energy CT (DE-CT) for lymph node staging and therapy response monitoring in lung cancer patients. Retrospective analysis of 27 patients with non-small cell lung carcinoma (NSCLC), who underwent dual-phase DE-CT before and after chemotherapy, was performed. Iodine uptake (mg/mL) and total iodine uptake (mg) were calculated using prototype software in the early (arterial) and late (venous) post-contrast circulatoryphase in 110 mediastinal lymph nodes. The arterial enhancement fraction (AEF) was calculated and compared with lymph node size and response to chemotherapy. A significant difference of AEF was observed between enlarged (90.4 %; 32.3-238.5 %) and non-enlarged (72.7 %; -37.5-237.5 %) lymph nodes (p = 0.044) before treatment onset. A significantly different change of AEF in responding (decrease of 26.3 %; p = 0.022) and non-responding (increase of 43.0 %; p = 0.031) lymph nodes was demonst
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FP - Other medical fields
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
European Radiology
ISSN
0938-7994
e-ISSN
—
Volume of the periodical
24
Issue of the periodical within the volume
8
Country of publishing house
DE - GERMANY
Number of pages
8
Pages from-to
1981-1988
UT code for WoS article
000339271800032