Bio-activated titanium surface utilizable for mimetic bone implantation in dentistry - Part III: Surface characteristics and bone-implant contact formation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F07%3A00004114" target="_blank" >RIV/00216208:11150/07:00004114 - isvavai.cz</a>
Alternative codes found
RIV/44265786:_____/07:#0000021 RIV/00216208:11110/07:00010987 RIV/49777513:23520/07:00000287 RIV/00064165:_____/07:00002607
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Bio-activated titanium surface utilizable for mimetic bone implantation in dentistry - Part III: Surface characteristics and bone-implant contact formation
Original language description
This study was carried out to quantify the effect of an alkali-modified surface on the bone-implant interface formation during healing using an animal model. A total of 24 screw-shaped, self-tapping, (c.p.) titanium dental implants, divided into test group B-implants with alkali-modified surface (Bio surface) and control group M-implants with turned, machined surface, were inserted without pre-tapping in the tibiae of three beagle dogs.
Czech name
Bioaktivní povrch titanu je vhodný pro kostní implantáty v zubním lékařství - Část III. Povrchové charakteristiky a tvorba kontaktů mezi kostí a implantátem
Czech description
Tato studie kvantifikuje účinek alkalicky modifikovaného povrchu na tvorbu kontaktu mezi kostí a implantátem během procesu hojení za použití zvířecího modelu. Do kosti holenní 3 beaglů bylo vloženo celkem 24 vrutům podobných, samořezných, (c.p.) titanových zubních implantátů, které byly rozděleny do testovací skupiny B ? implantáty s alkalicky modifikovaným povrchem (Bio povrch) a kontrolní skupiny M ? implantáty se soustruženým povrchem.
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FP - Other medical fields
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/FT-TA%2F087" target="_blank" >FT-TA/087: Complex investigation of biomechanical conditions of the artifiacial skeletal replacements applications, evaluating of their failure reasons and proposal of conditions for increasing their stability in the human organism.</a><br>
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2007
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Physics and Chemistry of Solids
ISSN
0022-3697
e-ISSN
—
Volume of the periodical
68
Issue of the periodical within the volume
Spec.Iss
Country of publishing house
GB - UNITED KINGDOM
Number of pages
5
Pages from-to
841-845
UT code for WoS article
—
EID of the result in the Scopus database
—