Determination of pravastatin and pravastatin lactone in rat plasma and urine using UHPLC-MS/MS and microextraction by packed sorbent
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11150%2F12%3A10124845" target="_blank" >RIV/00216208:11150/12:10124845 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11160/12:10124845
Result on the web
<a href="http://www.sciencedirect.com/science/article/pii/S0039914011011118" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0039914011011118</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2011.12.043" target="_blank" >10.1016/j.talanta.2011.12.043</a>
Alternative languages
Result language
angličtina
Original language name
Determination of pravastatin and pravastatin lactone in rat plasma and urine using UHPLC-MS/MS and microextraction by packed sorbent
Original language description
A simple and reproducible method for the determination of pravastatin and pravastatin lactone in rat plasma and urine by means of ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) using deuterium labeled intemal standardsfor quantification is reported. Separation of analytes was performed on BEH C-18 analytical column (50 mm x 2.1 mm, 1.7 mu m), using gradient elution by mobile phase consisting of acetonitrile and 1 mM ammonium acetate at pH 4.0. Run time was 2 min. Quantification of analytes was performed using the SRM (selected reaction monitoring) experiment in ESI negative ion mode for pravastatin and in ESI positive ion mode for pravastatin lactone. Sample treatment consisted of a protein precipitation by ACN andmicroextraction by packed sorbent (MEPS) for rat plasma. Simple MEPS procedure was sufficient for rat urine. MEPS was implemented using the C8 sorbent inserted into a microvolume syringe, eVol hand-held automated analytical syringe and a
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Talanta
ISSN
0039-9140
e-ISSN
—
Volume of the periodical
90
Issue of the periodical within the volume
1
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
8
Pages from-to
22-29
UT code for WoS article
000301627300003
EID of the result in the Scopus database
—