Optimisation of an HPLC method for the simultaneous determination of pyrantel pamoate, praziquantel, fenbendazole, oxfendazole and butylhydroxyanisole using a phenyl stationary phase
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F12%3A10124375" target="_blank" >RIV/00216208:11160/12:10124375 - isvavai.cz</a>
Result on the web
<a href="http://pubs.rsc.org/en/content/articlepdf/2012/ay/c2ay05847b" target="_blank" >http://pubs.rsc.org/en/content/articlepdf/2012/ay/c2ay05847b</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/c2ay05847b" target="_blank" >10.1039/c2ay05847b</a>
Alternative languages
Result language
angličtina
Original language name
Optimisation of an HPLC method for the simultaneous determination of pyrantel pamoate, praziquantel, fenbendazole, oxfendazole and butylhydroxyanisole using a phenyl stationary phase
Original language description
A novel and simple isocratic reversed phase HPLC method with UV and fluorimetric detection for the simultaneous determination of the active anthelmintic components pyrantel pamoate, praziquantel, fenbendazole, its degradation product oxfendazole, and theantioxidant butylhydroxyanisole (BHA) has been developed and validated. The chromatography was performed using a Phenomenex Luna 3 mm phenyl-hexyl column (150 x 3.0 mm), and the mobile phase was composed of 0.5% triethylamine at pH 9.0 and acetonitrile55 : 45 (v/v) at a flow rate of 1.0 ml min(-1). The UV detection was performed at 290 nm for pyrantel, oxfendazole and fenbendazole and at 220 nm for praziquantel. For BHA, fluorescence detection was used with excitation and emission wavelengths of 287 nm and 322 nm, respectively. The method was validated and was applied for the determination of active compounds in various dosage forms of veterinary formulations.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Analytical Methods
ISSN
1759-9660
e-ISSN
—
Volume of the periodical
4
Issue of the periodical within the volume
6
Country of publishing house
GB - UNITED KINGDOM
Number of pages
6
Pages from-to
1592-1597
UT code for WoS article
000304768600020
EID of the result in the Scopus database
—