All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Optimisation of an in-tube solid phase microextraction method coupled with HPLC for determination of some oestrogens in environmental liquid samples using different capillary columns

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216208%3A11160%2F12%3A10124750" target="_blank" >RIV/00216208:11160/12:10124750 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.tandfonline.com/doi/pdf/10.1080/03067319.2011.585714" target="_blank" >http://www.tandfonline.com/doi/pdf/10.1080/03067319.2011.585714</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1080/03067319.2011.585714" target="_blank" >10.1080/03067319.2011.585714</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Optimisation of an in-tube solid phase microextraction method coupled with HPLC for determination of some oestrogens in environmental liquid samples using different capillary columns

  • Original language description

    A simple on-line method for simultaneous determination of some oestrogens including oestriol (E3), norethisterone (NORE), ethynylestradiol (EE2), D-norgestrel (NORG) and bisphenol A (BPA), in environmental liquid samples was developed by coupling in-tubesolid phase microextraction (in-tube SPME) to high-performance liquid chromatography with diode array (DAD) and fluorescence (FLD) detectors. Two capillary chromatographic columns (Supel-Q (TM) and Carboxen (TM) 1006 porous layer open tubular) were selected to develop this method. To achieve optimum extraction performance, several parameters were investigated including number of draw/eject cycles and the sample volume for each of the columns. Reproducibility was satisfactory for inter-and intra-day precision, yielding % RSDs of less than 10% and 7.6%, respectively. Limits of detection (LODs) and quantification (LOQs) for the proposed method using a DAD detector were achieved in the ranges of 0.04-0.63 ng mL(-1) and 0.12-1.9 ng mL(-1),

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/KJB601100901" target="_blank" >KJB601100901: MONITORING OF PHARMACEUTICALS IN WASTEWATERS USING UPLC-MS/MS TECHNIQUE</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2012

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    International Journal of Environmental Analytical Chemistry

  • ISSN

    0306-7319

  • e-ISSN

  • Volume of the periodical

    92

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    15

  • Pages from-to

    382-396

  • UT code for WoS article

    000301506600003

  • EID of the result in the Scopus database